Determination of perchlorate in infant formula by isotope dilution ion chromatography/tandem mass spectrometry

نویسندگان

  • Z. Wang
  • B.P.-Y. Lau
  • B. Tague
  • M. Sparling
  • D. Forsyth
چکیده

A sensitive and selective isotope dilution ion chromatography/tandem mass spectrometry (ID IC-MS/MS) method was developed and validated for the determination of perchlorate in infant formula. The perchlorate was extracted from infant formula by using 20 ml of methanol and 5 ml of 1% acetic acid. All samples were spiked with (18)O(4) isotope-labelled perchlorate internal standard prior to extraction. After purification on a graphitised carbon solid-phase extraction column, the extracts were injected into an ion chromatography system equipped with an Ionpac AS20 column for separation of perchlorate from other anions. The presence of perchlorate in samples was quantified by isotope dilution mass spectrometry. Analysis of both perchlorate and its isotope-labelled internal standard was carried out on a Waters Quattro Ultima triple quadrupole mass spectrometer operating in a multiple reaction monitoring (MRM) negative ionisation mode. The method was validated for linearity and range, accuracy, precision, sensitivity, and matrix effects. The limit of quantification (LOQ) was 0.4 µg l(-1) for liquid infant formula and 0.95 µg kg(-1) for powdered infant formula. The recovery ranged from 94% to 110% with an average of 98%. This method was used to analyse 39 infant formula, and perchlorate concentrations ranging from <LOQ to 13.5 µg l(-1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of melamine, ammeline, ammelide and cyanuric acid in infant formula purchased in Canada by liquid chromatography-tandem mass spectrometry

A liquid chromatography-tandem mass spectrometry-based isotope dilution method was developed for the analysis of the triazine compounds melamine (MEL), ammeline (AMN), ammelide (AMD) and cyanuric acid (CYA) in infant formula samples purchased in Canada in 2008 for the purpose of a combined exposure and risk assessment. Infant formula samples were extracted with 1:1 acetonitrile-water, cleaned u...

متن کامل

Quantitative determination of total L-carnitine in infant formula, follow-up formula, and raw materials by liquid chromatography with tandem mass spectrometry.

We developed a rapid and useful routine screening assay for total L-carnitine content in various infant formulas and materials by liquid chromatography coupled with a tandem mass spectrometric method (LC-MS/MS) and alkaline hydrolysis. For separation of L-carnitine, a multi-mode octadecylsilane (ODS) column was used that contained ODS ligands, anion ligands, and cation ligands to avoid using io...

متن کامل

Analysis of perchlorate in human urine using ion chromatography and electrospray tandem mass spectrometry.

Because of health concerns surrounding widespread exposure to perchlorate, we developed a sensitive and selective method for quantifying perchlorate in human urine using ion chromatography coupled with electrospray ionization tandem mass spectrometry. Perchlorate was quantified using a stable isotope-labeled internal standard ((18)O(4)-perchlorate) with excellent assay precision (coefficient of...

متن کامل

Determination of Melamine and Cyanuric Acid Residues in Infant Formula using LC-MS/MS

A liquid chromatography triple quadrupole tandem mass spectrometry (LC-MS/MS) method for residues of cyanuric acid (CYA) and melamine (MEL) developed by the Center for Veterinary Medicine (CVM) has been adapted for use with infant formula. This method consists of an initial extraction with 2.5% aqueous formic acid, followed by a series of filtration, centrifugation, and dilution steps. Both com...

متن کامل

Rapid determination of serum testosterone by liquid chromatography-isotope dilution tandem mass spectrometry and a split sample comparison with three automated immunoassays.

OBJECTIVES To develop a rapid convenient-to-implement high performance liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for determination of serum testosterone concentration in routine clinical laboratories. METHODS Following extraction by organic solvents, an Agilent 1200 Series HPLC system coupled to an API 5000 mass spectrometer equipped with an atmospher...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2011