An accumulative x-ray streak camera with sub-600-fs temporal resolution and 50-fs timing jitter
نویسندگان
چکیده
Related Articles Compact x-ray microradiograph for in situ imaging of solidification processes: Bringing in situ x-ray micro-imaging from the synchrotron to the laboratory Rev. Sci. Instrum. 82, 105108 (2011) Simultaneous sample and spatial coherence characterisation using diffractive imaging Appl. Phys. Lett. 99, 154103 (2011) Heat transfer simulation and thermal measurements of microfabricated x-ray transparent heater stages Rev. Sci. Instrum. 82, 093904 (2011) Linac Coherent Light Source soft x-ray materials science instrument optical design and monochromator commissioning Rev. Sci. Instrum. 82, 093104 (2011) X-ray beam induced current method at the laboratory x-ray source Rev. Sci. Instrum. 82, 093702 (2011)
منابع مشابه
A sub-picosecond accumulating streak camera for x-rays
An x-ray streak camera system uses a laser triggered photo-conductive switch to synchronize the high voltage ramp applied to its sweep plates to the photo-excitation of a sample. This technique allows the jitter between successive sweeps to be kept below 100 fs compared to over 1 ps using classical methods. By accumulating a stable pulsed x-ray signal over many sweeps, a very high dynamic range...
متن کاملA compact streak camera for 150 fs time resolved measurement of bright pulses in ultrafast electron diffraction.
We have developed a compact streak camera suitable for measuring the duration of highly charged subrelativistic femtosecond electron bunches with an energy bandwidth in the order of 0.1%, as frequently used in ultrafast electron diffraction (UED) experiments for the investigation of ultrafast structural dynamics. The device operates in accumulation mode with 50 fs shot-to-shot timing jitter, an...
متن کاملUltrafast x-ray diffraction using a streak-camera detector in averaging mode.
We demonstrate an apparatus for measuring time-dependent x-ray diffraction. X-ray pulses from a synchrotron are diffracted by a pair of Si(111) crystals and detected with an x-ray streak camera that has single-shot resolution of better than 1 ps. The streak camera is driven by a photoconductive switch, which is triggered by 100-fs laser pulses at a repetition rate of 1 kHz. The laser and the st...
متن کاملAn ultrafast x-ray detector system at an elliptically polarizing undulator beamline
An ultrafast x-ray detector system is under development at Lawrence Berkeley National Laboratory (LBNL) for application primarily to study of ultrafast magnetization dynamics. The system consists of a fs laser, an x-ray streak camera and an elliptically polarization undulator (EPU) beamline. Polarized x-rays from an EPU can be used to measure x-ray magnetic circular dichroism (XMCD) of a sample...
متن کاملLaser and synchrotron radiation pump–probe x-ray diffraction experiments
Recent developments have allowed x-ray diffraction techniques at synchrotron radiation facilities to be employed with a temporal resolution of around 1 ps. These developments are the availability of firstly, high brightness third-generation x-ray sources, secondly, passively mode-locked lasers with 100 fs temporal duration and thirdly, averaging streak cameras with sub-picosecond temporal resol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011