Adaptation by normal listeners to upward spectral shifts of speech: implications for cochlear implants.
نویسندگان
چکیده
Multi-channel cochlear implants typically present spectral information to the wrong "place" in the auditory nerve array, because electrodes can only be inserted partway into the cochlea. Although such spectral shifts are known to cause large immediate decrements in performance in simulations, the extent to which listeners can adapt to such shifts has yet to be investigated. Here, the effects of a four-channel implant in normal listeners have been simulated, and performance tested with unshifted spectral information and with the equivalent of a 6.5-mm basalward shift on the basilar membrane (1.3-2.9 octaves, depending on frequency). As expected, the unshifted simulation led to relatively high levels of mean performance (e.g., 64% of words in sentences correctly identified) whereas the shifted simulation led to very poor results (e.g., 1% of words). However, after just nine 20-min sessions of connected discourse tracking with the shifted simulation, performance improved significantly for the identification of intervocalic consonants, medial vowels in monosyllables, and words in sentences (30% of words). Also, listeners were able to track connected discourse of shifted signals without lipreading at rates up to 40 words per minute. Although we do not know if complete adaptation to the shifted signals is possible, it is clear that short-term experiments seriously exaggerate the long-term consequences of such spectral shifts.
منابع مشابه
Resistance to learning binaurally mismatched frequency-to-place maps: implications for bilateral stimulation with cochlear implants.
Simulations of monaural cochlear implants in normal hearing listeners have shown that the deleterious effects of upward spectral shifting on speech perception can be overcome with training. This study simulates bilateral stimulation with a unilateral spectral shift to investigate whether listeners can adapt to upward-shifted speech information presented together with contralateral unshifted inf...
متن کاملSpeech Intelligibility of Cochlear-Implanted and Normal-Hearing Children
Introduction: Speech intelligibility, the ability to be understood verbally by listeners, is the gold standard for assessing the effectiveness of cochlear implantation. Thus, the goal of this study was to compare the speech intelligibility between normal-hearing and cochlear-implanted children using the Persian intelligibility test. Materials and Methods: Twenty-six cochlear-implanted childre...
متن کاملCorrelation between Auditory Spectral Resolution and Speech Perception in Children with Cochlear Implants
Background: Variability in speech performance is a major concern for children with cochlear implants (CIs). Spectral resolution is an important acoustic component in speech perception. Considerable variability and limitations of spectral resolution in children with CIs may lead to individual differences in speech performance. The aim of this study was to assess the correlation between auditory ...
متن کاملSpeech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants.
Speech recognition was measured as a function of spectral resolution (number of spectral channels) and speech-to-noise ratio in normal-hearing (NH) and cochlear-implant (CI) listeners. Vowel, consonant, word, and sentence recognition were measured in five normal-hearing listeners, ten listeners with the Nucleus-22 cochlear implant, and nine listeners with the Advanced Bionics Clarion cochlear i...
متن کاملSpeech Perception in Tones and Noise via Cochlear Implants Reveals Influence of Spectral Resolution on Temporal Processing
Under normal conditions, human speech is remarkably robust to degradation by noise and other distortions. However, people with hearing loss, including those with cochlear implants, often experience great difficulty in understanding speech in noisy environments. Recent work with normal-hearing listeners has shown that the amplitude fluctuations inherent in noise contribute strongly to the maskin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 106 6 شماره
صفحات -
تاریخ انتشار 1999