Evaluation of three commercial microclimate cooling systems.

نویسندگان

  • B S Cadarette
  • B S DeCristofano
  • K L Speckman
  • M N Sawka
چکیده

Three commercially available microclimate cooling systems were evaluated for their ability to reduce heat stress in men exercising in a hot environment while wearing high insulative, low permeability clothing. Five male volunteers performed three 180-min experiments (three repeats of 10 min rest, 50 min walking at 440 watts) in an environment of 38 degrees C dry bulb (Tdb), 12 degrees C dew point (Tdp). The cooling systems were: 1) ILC Dover Model 19 Coolvest (ILC), mean inlet temperature 5.0 degrees C; 2) LSSI Coolhead (LSSI), mean inlet temperature 14.5 degrees C; and 3) Thermacor Cooling Vest (THERM), mean inlet temperature 28.3 degrees C. Endurance time (ET), heart rate (HR), rectal temperature (Tre), mean skin temperature (Tsk), sweating rate (SR), rated perceived exertion (RPE), and thermal sensation (TS) were measured. A computer model prediction of ET with no cooling was 101 min. ET was greater (p less than 0.01) with ILC (178 min) than THERM (131 min) which was greater (p less than 0.01) than LSSI (83 min). The subjects self terminated on all LSSI tests because of headaches. Statistical analyses were performed on data collected at 60 min to have values on all subjects. There were no differences in HR, Tre, SR, or TS values among the cooling vests. The subjects' Tsk was lower (p less than 0.05) for the LSSI than THERM; and RPE values were higher (p less than 0.05) for LSSI than the other two vests. These data suggest an improved physiological response to exercise heat stress with all three commercial systems with the greatest benefit in performance time provided by the ILC cooling system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficfncy of Combinations of Cooling for Microclimate Cooling Suit Design, Tested in Man at 100°f with Exercise

A recent concern in hazardous materials containment, removal, and military operations has been the heat and work stress imposed on personnel wearing chemical and biological protective clothing (Chemical and Biological Protection Suit, Carbon Sphere #8415-01-333-7578 and gas maskkowl, MSA91J012-013; CBR). Several microclimate-cooling systems have been tested as possible solutions (1). Although t...

متن کامل

Optimization of Liquid Microclimate Cooling Systems: Importance of Skin Temperature

Personal protective equipment (PPE) markedly increases heat strain, reduces work performance, and increases the incidence of heat casualties. Microclimate cooling (MCC) technologies have been successfully used to alleviate heat strain and sustain performance (Pandolf et al., 1995) (Figure 1) in mounted soldiers, but cooling limitations, power and weight restrictions do not currently make this t...

متن کامل

Dynamic Modeling of Microclimate and Environmental Control Strategies in a Greenhouse Coupled with a Heat Pump System

The purpose of this study was to develop and validate a dynamic simulation model to be employed in accurate prediction of microclimate in a greenhouse as a function of dynamic environmental factors. The model has options to evaluate the effects of location, time of the year, orientation, single and double polyethylene glazings, conventional and heat pump heating and cooling systems, open and co...

متن کامل

Thermal Manikin Evaluation of Liquid Cooling Garments Intended for Use in Hazardous Waste Management

Thermal manikins are valuable tools for quantitatively evaluating the performance of protective clothing ensembles and microclimate cooling systems. The goal of this investigation was to examine the performance of Coretech personal cooling systems, designed to reduce the effects of physiological and environmental heat stress, using a sweating thermal manikin. A sweating manikin takes into accou...

متن کامل

Microclimate Conditions and Space Use Variations

This paper is a part of study about the impact of the microclimate on the space use and the user’s behaviours. The purpose of our study is to get an in-depth understanding of how people use out door public spaces in different climatic conditions, how their behaviour and perception of the space change with the climatic variations. We have employed a multi-method approach which combines a “qualit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aviation, space, and environmental medicine

دوره 61 1  شماره 

صفحات  -

تاریخ انتشار 1990