The effects of different mesh generation methods on computational fluid dynamic analysis and power loss assessment in total cavopulmonary connection.
نویسندگان
چکیده
The flow field and energetic efficiency of total cavopulmonary connection (TCPC) models have been studied by both in vitro experiment and computational fluid dynamics (CFD). All the previous CFD studies have employed the structured mesh generation method to create the TCPC simulation model. In this study, a realistic TCPC model with complete anatomical features was numerically simulated using both structured and unstructured mesh generation methods. The flow fields and energy losses were compared in these two meshes. Two different energy loss calculation methods, the control volume and viscous dissipation methods, were investigated. The energy losses were also compared to the in vitro experimental results. The results demonstrated that: (1) the flow fields in the structured model were qualitatively similar to the unstructured model; (2) more vortices were present in the structured model than in the unstructured model; (3) both models had the least energy loss when flow was equally distributed to the left and right pulmonary arteries, while high losses occurred for extreme pulmonary arterial flow splits; (4) the energy loss results calculated using the same method were significantly different for different meshes; and (5) the energy loss results calculated using different methods were significantly different for the same mesh.
منابع مشابه
Computational haemodynamic analysis of patient-specific virtual operations for total cavopulmonary connection with dual superior venae cavae.
OBJECTIVES This study set out to design different types of total cavopulmonary connections (TCPC) with dual superior venae cavae (SVC), taking into account different sites for anastomosis from venae cavae to pulmonary arteries (PAs), and to compare haemodynamic features in these virtual operative designs. METHODS The geometries of bilateral bidirectional Glenn (BBDG) connection and inferior v...
متن کاملFontan hemodynamics: importance of pulmonary artery diameter.
OBJECTIVE We quantify the geometric and hemodynamic characteristics of extracardiac and lateral tunnel Fontan surgical options and correlate certain anatomic characteristics with their hemodynamic efficiency and patient cardiac index. METHODS AND RESULTS The study was conducted retrospectively on 22 patients undergoing Fontan operations (11 extracardiac and 11 lateral tunnel operations). Tota...
متن کاملThe development and assessment of solar-driven Tri-generation system energy and optimization of criteria comparison
In this research, the thermodynamic investigation of the tri-generation system is performed by the first and second law of Thermodynamics. The trigeneration system under study consists of three subsystems including the solar subsystem, Kalina subsystem and lithium bromide-water absorption chiller subsystem. The proposed system generates power, cooling and hot water using solar energy. The syste...
متن کاملDynamical stability of cantilevered pipe conveying fluid in the presence of linear dynamic vibration absorber
When the velocity of fluid flow in a cantilevered pipe is successively increased, the system may become unstable and flutter instability would occur at a critical flow velocity. This paper is concerned with exploring the dynamical stability of a cantilevered fluid-conveying pipe with an additional linear dynamic vibration absorber (DVA) attachment. It is endeavoured to show that the stability o...
متن کاملIn vitro flow analysis of a patient-specific intraatrial total cavopulmonary connection.
BACKGROUND Understanding the hemodynamics of the total cavopulmonary connection may lead to further optimization of the connection design and surgical planning, which in turn may lead to improved surgical outcome. Although most experimental and numerical investigations have mainly focused on somewhat simplified geometries, investigation of the flow field of true anatomic configurations is neces...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanical engineering
دوره 126 5 شماره
صفحات -
تاریخ انتشار 2004