Evaluation of Renal Oxygenation in Normal Korean Volunteers Using 3.0 T Blood Oxygen Level-Dependent MRI
نویسندگان
چکیده
Purpose : Renal blood oxygen level-dependent (BOLD) MRI has been used in the evaluation of renal oxygenation. We tried to provide the normal R2* value of the human kidney with 3.0 T, and evaluated the differences in R2* values according to gender and location. Materials and Methods: Twenty-four healthy volunteers underwent BOLD MRI at 3.0 T. Multi gradient echo-echo planar imaging sequence with seventeen echoes was used. After generation of the T2* map, the R2* was calculated. The statistical differences in R2* values between the cortex and medulla, males and females, and the right and left kidney were analyzed. The regional differences of R2* within the both kidneys were evaluated respectively. Results: BOLD MRI was successful in all participants. No gross artifact interfered with R2* measurement. The mean R2* at 3.0 T was 17.1 ± 2.60 s in the cortex and 27.7 ± 4.83 s in the medulla (p < 0.001). The R2* value in the medulla was significantly higher in the male than female volunteers (p = 0.025). There were no statistical differences of R2* according to the side and location in the kidney (p = 0.197). Conclusion: Renal BOLD MRI can be efficiently performed with 3.0 T MRI. Renal medullary hypoxia is present in normal volunteers. Our results may be used as reference values in the evaluation of pathologic conditions using BOLD MRI. Index words : Blood oxygen level-dependent MRI∙Kidney∙Normal
منابع مشابه
Magnetic Resonance Imaging–Derived Renal Oxygenation and Perfusion During Continuous, Steady‐State Angiotensin‐II Infusion in Healthy Humans
BACKGROUND The role of kidney hypoxia is considered pivotal in the progression of chronic kidney disease. A widely used method to assess kidney oxygenation is blood oxygen level dependent (BOLD)-magnetic resonance imaging (MRI), but its interpretation remains problematic. The BOLD-MRI signal is the result of kidney oxygen consumption (a proxy of glomerular filtration) and supply (ie, glomerular...
متن کاملIn vivo measurement of blood oxygen saturation using magnetic resonance imaging: a direct validation of the blood oxygen level-dependent concept in functional brain imaging.
A novel noninvasive magnetic resonance imaging (MRI) method was developed to determine in vivo blood oxygen saturation and its changes during motor cortex activation in small cerebral veins. Specifically, based on susceptibility measurements in the resting states, pial veins were found to have a mean oxygen saturation of Yrest=0.544+/-0.029 averaged over 14 vessels in 5 volunteers. During activ...
متن کاملAngiotensin II decreases the renal MRI blood oxygenation level-dependent signal.
Acute experimental reduction of renal blood flow decreases the renal blood oxygenation level-dependent (BOLD) MRI signal in animals. Angiotensin II also reduces renal blood flow, but the ability of BOLD MRI to dynamically detect this response has not yet been investigated in humans. Six healthy male volunteers underwent an individual dose-finding study to identify the intravenous doses of angio...
متن کاملBlood Oxygenation Level-Dependent MRI to Assess Renal Oxygenation in Renal Diseases: Progresses and Challenges
BOLD-MRI (blood oxygenation-level dependent magnetic resonance imaging) allows non-invasive measurement of renal tissue oxygenation in humans, without the need for contrast products. BOLD-MRI uses the fact that magnetic properties of hemoglobin depend of its oxygenated state:: the higher local deoxyhemoglobin, the higher the so called apparent relaxation rate R2* (sec-1), and the lower local ti...
متن کاملComparison of 1.5 and 3 T BOLD MR to study oxygenation of kidney cortex and medulla in human renovascular disease.
OBJECTIVES Imaging of the kidney using blood oxygen level dependent MR presents a major opportunity to examine differences in tissue oxygenation within the cortex and medulla applicable to human disease. We sought to define the differences between regions within kidneys and to optimize selection of regions of interest for study with 1.5 and 3 Tesla systems. MATERIALS AND METHODS Studies in 38...
متن کامل