Radiation-Induced Second Cancer Risk from External Beam Photon Radiotherapy for Head and Neck Cancer: Impact on in-Field and Out-of-Field Organs
نویسندگان
چکیده
The purpose of this paper is to provide data on development of second primary cancers within or adjacent to tissue irradiated in the treatment of primary head and neck cancers using different techniques and modalities. Materials and methods: We selected five patients with HandN tumors located in base of the tongue for risk assessment. In order to examine the impact of choices of various planning techniques, numbers of beams and beam energy used in treatment plans - 7 and 9 field Intensity modulated radiotherapy (IMRT) plans using 6MV and 10 MV beam energies and a 6MV Volumetric modulated arc therapy (VMAT) plans were planned. Out-of-field measurements for secondary photon doses for the treatment plans were measured using diode-dosimeters and solid water slabs. Differential dose-volume histograms (DVH) for all 5 patients and 5 techniques, were exported and used to calculate organ equivalent dose (OAR), excess absolute risk (EAR), and life-time attributable risk (LAR) for in-field organs. Results: For all treatment plans, the DVH showed clinically acceptable values; adequate clinical target coverage and dose constraints were met for all organs at risk. There was a clear advantage for the VMAT plan; it provided superior organ at risk (OAR) sparing and adequate target coverage. VMAT has relatively low monitor units at 0.93±0.034 times 7F6. The average percentage scattered to prescription doses for the five patients at 15, 30, 45, 60 and 75 cm from the isocenter were 0.9212 ± 0.115, 0.2621 ± 0.080, 0.1617 ± 0.057, 0.0936 ± 0.026, 0.0296 ± 0.014, for VMAT. Conclusion: Organ-specific LAR was higher with VMAT compared to 7F6 for skin. 6-MV VMAT is an acceptable alternative to IMRT for HandN cancer and offers advantages in terms of sparing adjacent OAR.
منابع مشابه
Out-Of-Field Dose Measurement and Second Cancer-Risk Estimation Following External Beam Radiotherapy and Brachytherapy for Cervical Cancer Treatment: A Phantom Study
Introduction: The present study aimed to measure the scatter and leakage dose received by out-of-field organs while delivering Radiotherapy (RT) treatment of cervical cancer. Moreover, this study estimated the risk of second cancer (SC). The doses to out-of-field organs were measured using a lithium fluoride (TLD 100) dosimeter while delivering External Beam Radiothera...
متن کاملComparison of Absorbed Dose in Thyroid and Lens as Organs at Risk Between in vivo Dosimetry and 3-D Treatment Planning Calculation in Head and Neck Radiotherapy by Linac Beam
Introduction: Critical organs and structures may receive significant amounts of irradiation even if they are not the target of radiotherapy or located outside the treatment field. Although the sensitive thyroid gland and lens are not directly the targets of treatment, they can be affected by irradiation during the treatment of tumours in head and neck region. The purpose of thi...
متن کاملEstimation of the thyroid secondary cancer risk on the patient of standard breast external beam radiotherapy
Introduction: The purpose of this study was to estimate the secondary cancer risk of thyroid for standard radiotherapy methods which are commonly used for breast cancer patients. Materials and Methods: Sixty-four breast cancer patients (their age range was around 50 years old) who referred to Seyed- Al- Shohada hospital (Isfahan, Iran) were included in this ...
متن کاملRadiation-induced Hypothyroidism in Head and Neck Malignancy
Background and Objective: Hypothyroidism is a known consequence of the external beam radiotherapy to the neck encompassing the thyroid gland for over 40 years. The aim of this study was to find out the incidence of hypothyroidism in patients with head and neck cancer treated with radiotherapy, when radia...
متن کاملInfluence of Compensator Thickness and Field Size on Buildup factor of a Brass Compensator for Intensity- Modulated Radiation Therapy
Introduction: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as...
متن کامل