Stethoscope disinfection campaign in a Nigerian teaching hospital:results of a before-and-after study.

نویسندگان

  • Chigozie J Uneke
  • Chinwendu D Ndukwe
  • Kingsley O Nwakpu
  • Richard C Nnabu
  • Cletus D Ugwuoru
  • Nittita Prasopa-Plaizier
چکیده

INTRODUCTION This study aimed to assess the impact of a stethoscope disinfection sensitization campaign among doctors and nurses in a Nigerian teaching hospital. METHODOLOGY The design was a before-and-after study. Pre-program measurements were used to provide a baseline against which the post-program results were compared. Interventions that promoted compliance with stethoscope disinfection practice that were implemented included training and education on stethoscope disinfection and introduction of 70% isopropyl alcohol disinfectant at points-of-care places. Microbiological assessment of stethoscopes used by health workers was conducted after the intervention and the outcome was compared with the pilot study results. RESULTS After the intervention, of the 89 stethoscopes screened, 18 (20.2%) were contaminated with bacterial agents. A higher prevalence of stethoscope contamination was observed among stethoscopes from the intensive care unit (66.7%), the VIP unit (50%), and the antenatal unit (37.5%). The main isolates were Staphylococcus aureus (44.4%) and Escherichia coli (50%). The antibiotic sensitivity assessment indicated that the bacterial isolates were resistant to nearly all the antibiotics tested. All the 89 health workers whose stethoscopes were screened after the intervention admitted to cleaning their stethoscopes after seeing each patient, representing a compliance rate of 100%, unlike the 15% compliance at the pilot phase. The baseline stethoscope contamination rate was 78.5% versus 20.2% post-intervention. CONCLUSIONS Training and education and introduction of alcohol-based disinfectants inexpensive but very effective methods to improve stethoscope disinfection compliance among health workers in low-income settings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Antibodies against Rubella Virus in a Mass Campaign Vaccination in Tehran, Iran

Background and Aims: Vaccine is available, but fetal infection with rubella virus is still a main cause of congenital birth defects and mental retardation in many countries. Mass vaccination campaigns and Expanded Program of Immunization (EPI) have increased vaccine coverage in the world with a substantial impact on the reduction of rubella infections, such as Congenital Rubella Syndrome (CRS)....

متن کامل

Predictors of stethoscope disinfection among pediatric health care providers.

BACKGROUND Stethoscopes are contaminated with bacteria, but predictors of stethoscope disinfection frequency are unknown. We sought to describe health care provider stethoscope disinfection attitudes and practices and determine predictors of frequent disinfection. METHODS We used an anonymous online survey of nurses, nurse practitioners, and physicians at a pediatric hospital. We assessed fre...

متن کامل

Efficacy of the disinfectants and antiseptics used in hospitals

Background: One of the major causes of increasing nosocomial infections is misusing disinfectants and antiseptics in hospitals. The aim of this study was to evaluate the efficacy of disinfectants and antiseptics using in injections and dressing wards, operation rooms and kitchen of Hamedan hospitals. Materials and Methods: In this study 742 samples were collected before and after disinfect...

متن کامل

Time Effectiveness of Ultraviolet C Light (UVC) Emitted by Light Emitting Diodes (LEDs) in Reducing Stethoscope Contamination

Today it is well demonstrated that stethoscopes can be as contaminated as hands, which are a recognized source of Health-Care Associated Infections (HCAIs). Ultraviolet C (UVC) light has proven disinfection capacity and the innovative UVC technology of Light Emitting Diode (LED) shows several potential benefits. To verify whether the use of UVC LEDs is effective and reliable in stethoscope memb...

متن کامل

بررسی فراوانی آلودگی میکروبی دستگاه های بیومیکروسکوپ چشمی Slit-lamp موجود در مرکز چشم پزشکی بیمارستان فرشچیان همدان و ارزیابی ضد عفونی کننده های موجود

Background and Objectives: The aim of this study is the evaluation of bacterial contamination of Slit-lamps in Eye Centers of Farshchian Hospital and assessment of the current disinfectants on isolated bacteria from apparatuses. Methods: In a cross-sectional study, 400 samples were collected from different parts of Slit-lamps (200 samples before and 200 samples after disinfection). The samp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of infection in developing countries

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 2014