Chloramination is often the disinfection regimen of choice for extended drinking water systems. However, this process is prone to instability due to the growth of nitrifying bacteria. This is the first study to use alternative approaches for rapid investigation of chloraminated drinking water system instability in which flow cytometric cell sorting of bacteria with intact membranes (membrane-intact fraction) (BacLight kit) or with active esterases (esterase-active fraction) (carboxyfluorescein diacetate) was combined with 16S rRNA gene-directed PCR and denaturing gradient gel electrophoresis (DGGE). No active bacteria were detected when water left the water treatment plant (WTP), but 12 km downstream the chloramine residual had diminished and the level of active bacteria in the bulk water had increased to more than 1 x 10(5) bacteria ml(-1). The bacterial diversity in the system was represented by six major DGGE bands for the membrane-intact fraction and 10 major DGGE bands for the esterase-active fraction. PCR targeting of the 16S rRNA gene of chemolithotrophic ammonia-oxidizing bacteria (AOB) and subsequent DGGE and DNA sequence analysis revealed the presence of an active Nitrosospira-related species and Nitrosomonas cryotolerans in the system, but no AOB were detected in the associated WTP. The abundance of active AOB was then determined by quantitative real-time PCR (qPCR) targeting the amoA gene; 3.43 x 10(3) active AOB ml(-1) were detected in the membrane-intact fraction, and 1.40 x 10(4) active AOB ml(-1) were detected in the esterase-active fraction. These values were several orders of magnitude greater than the 2.5 AOB ml(-1) detected using a routine liquid most-probable-number assay. Culture-independent techniques described here, in combination with existing chemical indicators, should allow the water industry to obtain more comprehensive data with which to make informed decisions regarding remedial action that may be required either prior to or during an instability event.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heterotrophic Bacteria Count Index in Drinking Water and Possibility of Biofilm Formation in Household Drinking Water Treatment Devices in Sari, Iran

 Background and purpose: Household drinking water treatment devices are becoming commonplace to improve the quality of drinking water, remove odor, taste, turbidity and color, pathogenic organisms, toxic chemicals, organic matter, and carcinogenic pollutants. This study aimed at investigating the Heterotrophic plate count (HPC) in drinking water and possibility of biofilm formation in household...

متن کامل

Monochloramine Cometabolism by Nitrifying Biofilm Relevant to Drinking Water

2016 © American Water Works Association JOURNAL AWWA JULY 2016 | 108:7 Chloramine use is widespread in US drinking water distribution systems as a secondary disinfectant, and its use is predicted to increase with the final implementation of the Stage 2 Disinfectants and Disinfection Byproducts Rule (USEPA 2005). Chloramination is beneficial from the perspective of controlling formation of regul...

متن کامل

Effect of pH, Chlorine Residual and Turbidity on the Microbial Bio Indicators of Drinking Water Network

Abstract Background and objective: Bioindicators of drinking water are always influenced by physical and chemical factors such as turbidity and chlorine.  Considering the assessment of drinking water quality is based on residual chlorine, E.coli, heterotrophic bacteria and turbidity.  We aimed to evaluate the effect of pH, chlorine residual and turbidity on the microbial ...

متن کامل

باکتری‌های هتروتروف در آب آشامیدنی شهر تبریز

Background and Aim: Recently the use of heterotrophic plate count (HPC) has received much attention as a supplementary indicator of the MPN test in water quality control. The US Environmental Protection Agency (USEPA) has declared 500 cfu/mL as the maximum acceptable level for heterotrophic bacteria in distribution networks. Currently the HPC determination is not among the routine control items...

متن کامل

بررسی آلودگی باکتریایی در آب‌های بطری شده و مقایسه آن با آب آشامیدنی شبکه توزیع شهر سمنان در سال 91

Background and purpose: Heterotrophic plate count (HPC) is commonly used to assess the general microbiological quality of drinking water. HPC must be less than 500 colonies per milliliter in drinking water. The aim of this study was to compare the heterotrophic bacteria of bottled water and drinking water distribution system and their relationship with water quality parameters. Materials and m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 71 11  شماره 

صفحات  -