Sources of measurement error in an ECG examination: implications for performance-based assessments.

نویسندگان

  • David J Solomon
  • Gary Ferenchick
چکیده

OBJECTIVE To assess the sources of measurement error in an electrocardiogram (ECG) interpretation examination given in a third-year internal medicine clerkship. DESIGN Three successive generalizability studies were conducted. (1) Multiple faculty rated student responses to a previously administered exam. (2) The rating criteria were revised and study 1 was repeated. (3) The examination was converted into an extended matching format including multiple cases with the same underlying cardiac problem. RESULTS The discrepancies among raters (main effects and interactions) were dwarfed by the error associated with case specificity. The largest source of the differences among raters was in rating student errors of commission rather than student errors of omission. Revisions in the rating criteria may have helped increase inter-rater reliability slightly however, due to case specificity, it had little impact on the overall reliability of the exam. The third study indicated the majority of the variability in student performance across cases was in performance across cases within the same type of cardiac problem rather than between different types of cardiac problems. CONCLUSIONS Case specificity was the overwhelming source of measurement error. The variation among cases came mainly from discrepancies in performance between examples of the same cardiac problem rather than from differences in performance across different types of cardiac problems. This suggests it is necessary to include a large number of cases even if the goal is to assess performance on only a few types of cardiac problems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reducing Measurement Error in Nutrition Assessment: Potential Research Implications for Iran

Self-reported measures of dietary intake are prone to measurement error that may obscure the relationship of diet and disease. This review addresses strategies to decrease errors during collection of dietary data and statistical approaches to deal with measurement issues once the data are collected.  Examples from two US studies-- the Women’s Health Initiative (WHI) Dietary Modificat...

متن کامل

Score Generalizability of Writing Assessment: the Effect of Rater’s Gender

The score reliability of language performance tests has attracted increasing interest. Classical Test Theory cannot examine multiple sources of measurement error. Generalizability theory extends Classical Test Theory to provide a practical framework to identify and estimate multiple factors contributing to the total variance of measurement. Generalizability theory by using analysis of variance ...

متن کامل

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

A Unified Framework for Delineation of Ambulatory Holter ECG Events via Analysis of a Multiple-Order Derivative Wavelet-Based Measure

In this study, a new long-duration holter electrocardiogram (ECG) major events detection-delineation algorithm is described which operates based on the false-alarm error bounded segmentation of a decision statistic with simple mathematical origin. To meet this end, first three-lead holter data is pre-processed by implementation of an appropriate bandpass finite-duration impulse response (FIR) f...

متن کامل

TDL-based Wideband Beamforming for Radio Sources Close to the Array Endfire

Uniform linear array (ULA)-based tapped-delay line (TDL) structure has good performance metrics when the signal sources are located at the middle angles. It offers poor performance when the signal sources are close to the array endfire. In this paper, a new approach is proposed which offers higher performance and desired beamforming on TDL structure when the wideband uncorrelated radio sources ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Advances in health sciences education : theory and practice

دوره 9 4  شماره 

صفحات  -

تاریخ انتشار 2004