Optimization Algorithm for Single-Isocenter VMAT Stereotactic Radiosurgery for Multiple Brain Metastases

نویسنده

  • Alex Wells
چکیده

Objectives: Developing an optimal Stereotactic radiosurgery (SRS) plan for multiple brain metastases can be a labor intensive process. Single-isocenter multi-arc volumetrically modulated arc therapy (VMAT) has been used as an SRS technique, in which a Linear Accelerator (Linac) delivers targeted radiation along multiple arc angles as it rotates around the isocenter. Standardized arc angles without regards to patient-specific tumor anatomy may increase unnecessary exposure of normal brain to radiation due to "leakage" caused by a Multileaf Collimator's (MLC) inability to shield the space between 2 or more tumor targets in alignment. This results in increased volume of normal brain receiving low to intermediate dose of radiation. GammaKnife and CyberKnife largely circumvent this issue by their respective platform specific treatment technique. For Linac, we have developed an optimization algorithm to intelligently choose VMAT arc angles with the aim to reduce exposure to normal brain. Methods: For an optimal VMAT planning protocol, our optimization algorithm assumes a single isocenter with three or more arcs, each associated with a specific collimator rotation. A cost function, which simulates the amount of radiation leakage to normal brain, is computed. This is done by projecting 3D tumor locations onto 2D planes at each gantry position along an arc, followed by simulation of the MLC modulation in response to the angle-dependent 2D projections of tumor positions, and calculating the amount of normal brain exposed to radiation due to MLC leakage in a specific arc at a specific collimator angle. This is repeated for all possible combinations of arcs and collimator rotations. Ranking the cost function then enables a planner to obtain the optimal combinations of arc and collimator angles with the least leakage. Arc angles less than 15° apart are avoided in order to maintain radiosurgery dosimetry. Results: 2 recent cases with 5 and 7 tumors were used retrospectively in generating preliminary results. Standard arcs angles are defined at couch positions of 135, 180 and 225 degrees. Optimized arc and collimator angles resulted in 1% (0.5cc), 1% (2cc), 25% (330cc) and 18% (480cc) reduction in exposure of normal brain at V75%, V50%, V25% and V10%. Due to the steep dose gradient of SRS, higher dose volumes do not change significantly. However, as expected, the optimization algorithm resulted in significant reduction in exposure at lower dose levels. Preliminary results also show optimization can be further improved by selecting segments of arc rotations that are associated with particularly low levels of exposure from multiple arcs. By combining these smaller segments of multiple arcs, dosimetric parameters Open Access Abstract

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abstract ID: 18137 Title: Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery

ID: 18137 Title: Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery Purpose: To investigate the treatment of multiple brain metastases using stereotactic radiosurgery with single-isocenter volumetric modulated arc therapy (VMAT)...

متن کامل

Evaluation of a dedicated brain metastases treatment planning optimization for radiosurgery: a new treatment paradigm?

PURPOSE To investigate the feasibility of a novel dedicated treatment planning solution, to automatically target multiple brain metastases with a single isocenter and multiple inversely-optimized dynamic conformal arcs (DCA), and to benchmark it against the well-established multiple isocenter DCA (MIDCA) and volumetric modulated arc therapy (VMAT) approaches. MATERIAL AND METHODS Ten previous...

متن کامل

Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery

Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery by

متن کامل

Optimization of Treatment Geometry to Reduce Normal Brain Dose in Radiosurgery of Multiple Brain Metastases with Single–Isocenter Volumetric Modulated Arc Therapy

Treatment of patients with multiple brain metastases using a single-isocenter volumetric modulated arc therapy (VMAT) has been shown to decrease treatment time with the tradeoff of larger low dose to the normal brain tissue. We have developed an efficient Projection Summing Optimization Algorithm to optimize the treatment geometry in order to reduce dose to normal brain tissue for radiosurgery ...

متن کامل

Linac-based VMAT radiosurgery for multiple brain lesions: comparison between a conventional multi-isocenter approach and a new dedicated mono-isocenter technique

BACKGROUND Linac-based stereotactic radiosurgery or fractionated stereotactic radiotherapy (SRS/FSRT) of multiple brain lesions using volumetric modulated arc therapy (VMAT) is typically performed by a multiple-isocenter approach, i.e. one isocenter per lesion, which is time-demanding for the need of independent setup verifications of each isocenter. Here, we present our initial experience with...