Impact of Zernike-fit error on simulated high- and low-contrast acuity in keratoconus: implications for using Zernike-based corrections.

نویسندگان

  • Jason D Marsack
  • Konrad Pesudovs
  • Edwin J Sarver
  • Raymond A Applegate
چکیده

This study examines the extent to which a Zernike-based optical correction can restore acuity in keratoconus as a function of disease severity and contrast level. Increasingly complete Zernike corrections in the presence of Zernike-fit error were simulated. Acuity for keratoconic eyes with <60 D maximum corneal power reached 20/13 with a fifth-order Zernike correction under high-contrast conditions and exhibited a loss of 0.1 logMAR (minimum angle of resolution) (from 20/32 to 20/40) for low-contrast conditions. Acuity for keratoconic eyes with >60 D maximum corneal power approached 20/13 with sixth-tenth-order corrections under high-contrast conditions but did not return to similar levels with a tenth-order correction for low-contrast conditions. The results suggest that fit error affects visual performance for more difficult tasks and that restoring high-contrast acuity (20/16 or better) using a fifth-order Zernike correction is not limited by Zernike=fit error for over 88% of keratoconus cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Zernike polynomial fitting fails to represent all visually significant corneal aberrations.

PURPOSE It is assumed that wavefront error data arising from aberrometry are adequately described by a Zernike polynomial function, although this assumption has not been extensively tested. Inaccuracies in wavefront error may compromise clinical testing and refractive correction procedures. The current retrospective study correlates visual acuity with corneal wavefront error and with the residu...

متن کامل

Comparison of Zernike and Fourier wavefront reconstruction algorithms in representing the corneal aberration of normal and abnormal eyes

Purpose: The goal of this study was to investigate with what accuracy the Zernike and Fourier reconstruction algorithms can describe the corneal aberration in normal and abnormal eyes. Methods: Corneal topography (Orbscan IIz) was collected on 87 normal, 27 keratoconus, 9 penetrating keratoplasty (PKP), and 20 post-LASIK symptomatic eyes. Raw topography images were converted into elevation maps...

متن کامل

Pseudo Zernike Moment-based Multi-frame Super Resolution

The goal of multi-frame Super Resolution (SR) is to fuse multiple Low Resolution (LR) images to produce one High Resolution (HR) image. The major challenge of classic SR approaches is accurate motion estimation between the frames. To handle this challenge, fuzzy motion estimation method has been proposed that replaces value of each pixel using the weighted averaging all its neighboring pixels i...

متن کامل

Visual acuity as a function of Zernike mode and level of root mean square error.

BACKGROUND The coefficients of normalized Zernike expansion are orthogonal and reflect the relative contribution of each mode to the total root mean square (RMS) wavefront error. The relationship between the level of RMS wavefront error within a mode and its effect on visual performance is unknown. PURPOSE To determine for various levels of RMS wavefront error how each mode of the normalized ...

متن کامل

Comparison of Zernike and Fourier wavefront reconstruction algorithms in representing corneal aberration of normal and abnormal eyes.

PURPOSE To investigate the accuracy of Zernike and Fourier reconstruction algorithms in describing simulated wavefront data from corneal topography of normal and abnormal eyes. METHODS Corneal topography (Orbscan Ilz) was collected on 87 normal, 27 keratoconus, 9 penetrating keratoplasty (PKP), and 20 postoperative LASIK symptomatic eyes over a 6-mm pupil. Raw data from slit images were conve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Optical Society of America. A, Optics, image science, and vision

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2006