New Insights into Measurement Variability in Glaucomatous Visual Fields from Computer Modelling

نویسندگان

  • Richard A. Russell
  • David F. Garway-Heath
  • David P. Crabb
چکیده

OBJECTIVE To develop a model to simulate visual fields (VFs) in glaucoma patients, and to characterize variability of the Mean Deviation (MD) VF summary measurement using real VFs and simulations. METHODS Pointwise VF variability was previously approximated using longitudinal VF data (24-2 SITA Standard, Humphrey Field Analyzer) from 2,736 patients; these data were used to build a non-parametric model to simulate VFs. One million VF simulations were generated from 1,000 VFs (1,000 simulations per 'ground-truth' VF), and the variability of simulated MDs was characterized as a function of ground-truth MD and Pattern Standard Deviation (PSD). RESULTS The median (interquartile range, IQR) patient age and MD was 66 (56 to 75) years and -3.5 (-8.3 to -1.1) decibels, respectively. The inferred variability as a function of ground-truth MD and PSD indicated that variability, on average, increased rapidly as glaucoma worsened. However, the pattern of VF damage significantly affects the level of MD variability, with more than three-fold differences between patients with approximately the same levels of MD but different patterns of loss. CONCLUSIONS A novel approach for simulating VFs is introduced. A better understanding of VF variability will help clinicians to differentiate real VF progression from measurement variability. This study highlights that, overall, MD variability increases as the level of damage increases, but variability is highly dependent on the pattern of VF damage. Future research, using VF simulations, could be employed to provide benchmarks for measuring the performance of VF progression detection algorithms and developing new strategies for measuring VF progression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the effects of glaucomatous (POAG) damage on the mVEP parameters

Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...

متن کامل

Simulation of longitudinal threshold visual field data.

PURPOSE To describe and evaluate a computer model that simulates longitudinal visual field data. METHODS A computer model was designed using factors that influence thresholds of normal and glaucomatous visual fields. The simulation model was used to quantify the effects of fluctuation on the outcomes of pointwise linear regression by comparison with simulated gold standard data with no variab...

متن کامل

Reducing noise in suspected glaucomatous visual fields by using a new spatial filter

Visual field testing with automated perimetry is hampered by the amount of noise present in the readings. Here, we derive a physiologically accurate spatial filter to be applied to the data after patient examination. The filter was tested by a Virtual Eye computer simulation. By simulating series of stable fields it was shown that specificity of determining visual field changes was improved; wh...

متن کامل

Multi-Focus Image Fusion in DCT Domain using Variance and Energy of Laplacian and Correlation Coefficient for Visual Sensor Networks

The purpose of multi-focus image fusion is gathering the essential information and the focused parts from the input multi-focus images into a single image. These multi-focus images are captured with different depths of focus of cameras. A lot of multi-focus image fusion techniques have been introduced using considering the focus measurement in the spatial domain. However, the multi-focus image ...

متن کامل

Analysis of visual field progression in glaucoma.

BACKGROUND Despite the widespread use of computerised perimetry the diagnosis of visual field deterioration in following glaucoma patients over time remains particularly difficult. A new method of analysis using a novel graphical display of longitudinal field data is presented. METHODS A linear regression model of the luminance sensitivity at each stimulus location against time of follow up t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013