Straylight Measurements in Two Different Apodized Diffractive Multifocal Intraocular Lenses.
نویسندگان
چکیده
PURPOSE To evaluate differences in straylight between eyes implanted with a hydrophilic multifocal IOL (Seelens MF; Hanita Lenses, Hanita, Israel) and a hydrophobic multifocal IOL (SN6AD1; Alcon Laboratories, Inc., Fort Worth, TX). METHODS In a prospective cohort study, routinely obtained straylight measurements (C-Quant; Oculus Optikgeräte, Wetzlar, Germany) 3 months after standard phacoemulsification for either cataract or refractive lens procedures were compared. Patients were implanted with either the SeeLens MF IOL or the SN6AD1 IOL. Postoperative straylight values, visual acuity, and refractive outcomes were compared. RESULTS The SeeLens MF IOL was implanted in 84 eyes and the SN6AD1 IOL in 79 eyes. The difference in straylight was 0.08 (P = .01), with the SeeLens MF IOL having less straylight. Postoperative CDVA was logMAR -0.03 ± 0.06 in the SeeLens MF group, and logMAR -0.02 ± 0.08 in the SN6AD1 group. Mean postoperative refraction was +0.01 ± 0.43 and +0.06 ± 0.35 D, respectively. CONCLUSIONS The Seelens MF IOL showed a stray-light of log(s) 0.08 lower than the SN6AD1 IOL. In terms of spherical equivalent and visual acuity the lenses performed equally. More study will aid in understanding the causes and clinical impact of this difference.
منابع مشابه
Multifocal IOLs with apodized diffractive central zone and refractive periphery: optical performance and clinical outcomes
The apodized diffractive multifocal intraocular lens is one of the intraocular lens types currently available for the correction of presbyopia. The design of apodized diffractive multifocal intraocular lenses improves on the visual outcomes obtained with the full optic diffractive and refractive intraocular lenses. In addition to the visual improvements, apodized diffractive multifocal intraocu...
متن کاملEnergy balance in apodized diffractive multifocal intraocular lenses
The energy distribution between the distance and near images formed in a model eye by three different apodized diffractive multifocal intraocular lenses (IOLs) is experimentally determined in an optical bench. The model eye has an artificial cornea with positive spherical aberration (SA) similar to human cornea. The level of SA upon the IOL, which is pupil size dependent, is controlled using a ...
متن کاملComparative visual performance with monofocal and multifocal intraocular lenses
BACKGROUND To compare near, intermediate, and distance vision, and quality of vision using appropriate subjective questionnaires, when monofocal or apodized diffractive multifocal intraocular lenses (IOLs) are binocularly implanted. METHODS Patients with different binocular IOLs implanted were recruited after surgery and had their visual acuity tested, and quality of vision evaluated, at a si...
متن کاملAssessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses
Aim To better understand the phenomenon of dysphotopsia in patients implanted with multifocal intraocular lenses (IOLs). Methods Forty-five patients (aged 61.8±8.9 years) implanted bilaterally with Tecnis ZM900 (diffractive multifocal), Lentis Mplus MF30 (segmented refractive multifocal) or Softec-1 (monofocal) IOLs (each n=15) 4-6 months previously and who had achieved a good surgical outcom...
متن کاملEnergy distribution between distance and near images in apodized diffractive multifocal intraocular lenses.
PURPOSE To determine the energy distribution between the distance and near images formed in a model eye by spherical and aspheric apodized diffractive multifocal intraocular lenses (IOLs). METHODS The IOL was inserted in a model eye with an artificial cornea with positive spherical aberration (SA) similar to that of the human cornea. The energy of the distance and near images, as a function o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 31 11 شماره
صفحات -
تاریخ انتشار 2015