A clove-hitch suture method for small-caliber tendon ends.

نویسندگان

  • Edward Abraham
  • Alan League
  • Farid Amirouche
  • Nikhil Kulkarni
چکیده

BACKGROUND The choices of suture methods used to secure the end of a small-caliber tendon with a combination of suture materials passing through and looping around the tendon are not well documented. A secure stitch-tendon unit may be an important factor in preserving muscle function, by facilitating healing without gapping or failure. METHODS Five types of suture methods utilizing four or fewer passes through the tendon end were mechanically tested on 178 canine flexor digitorum profundus tendons. An Instron apparatus was used to test the load to failure. RESULTS The single and double clove-hitch suture methods demonstrated improved repair strength when compared with the three other methods studied in this small-caliber canine tendon model. CONCLUSIONS The single and double clove-hitch suture method better secured the end of a small-caliber tendon compared with other methods. CLINICAL RELEVANCE The single (pull-out) and double (non-pull-out) clove-hitch suture methods are reliable alternatives for the repair of small-caliber tendons.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhanced Zone II Flexor Tendon Repair through a New Half Hitch Loop Suture Configuration

This study evaluated the impact of a new half hitch loop suture configuration on flexor tendon repair mechanics. Cadaver canine flexor digitorum profundus tendons were repaired with 4- or 8-strands, 4-0 or 3-0 suture, with and without half hitch loops. An additional group underwent repair with half hitch loops but without the terminal knot. Half hitch loops improved the strength of 8-strand rep...

متن کامل

Intrasynovial flexor tendon repair: a biomechanical study of variations in suture application in human cadavera.

To improve the functional outcomes of intrasynovial tendon suture, prior experiments evaluated individual technical modifications used in the repair process. Few studies, however, have assessed the combinatorial effects of those suture modifications in an integrated biomechanical manner, including a sample size sufficient to make definitive observations on repair technique. Two hundred fifty-si...

متن کامل

A new head and neck surgical drain fixation technique.

We describe a simple technique of drain fixation in head and neck surgery using a beaded 2/0 nylon suture and a 'clove hitch' to achieve a non-slip fixation to the drain.

متن کامل

A biomechanical study of different techniques in medial patellofemoral ligament reconstruction

Purpose: The purpose of this study was to compare the ultimate failure load, stiffness and elongation of 3 different MPFL patellar fixation techniques: suture anchor, sutured tendon (a semi-tunnel technique, the free ends were sutured) and folio tendon (a semi-tunnel technique, the folio ends were passed through by suture). Materials and methods: We used six fresh-frozen cadaveric knees, each o...

متن کامل

Looped versus single-stranded flexor tendon repairs: a cadaveric mechanical study.

PURPOSE To compare the tensile properties of 4-strand modified Kessler flexor tendon repairs using a looped or single-stranded suture. METHODS We evaluated the mechanical properties of 4-strand Kessler zone II core suture repairs using either looped or single-stranded suture in human flexor digitorum profundus and flexor pollicis longus tendons. Forty repairs were performed on tendons from bi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 94 14  شماره 

صفحات  -

تاریخ انتشار 2012