Utility of B-natriuretic peptide in detecting diastolic dysfunction: comparison with Doppler velocity recordings.
نویسندگان
چکیده
BACKGROUND Although Doppler echocardiography has been used to identify abnormal left ventricular (LV) diastolic filling dynamics, inherent limitations suggest the need for additional measures of diastolic dysfunction. Because data suggest that B-natriuretic peptide (BNP) partially reflects ventricular pressure, we hypothesized that BNP levels could predict diastolic abnormalities in patients with normal systolic function. METHODS AND RESULTS We studied 294 patients referred for echocardiography to evaluate ventricular function. Patients with abnormal systolic function were excluded. Cardiologists making the assessment of LV function were blinded to BNP levels. Patients were classified as normal, impaired relaxation, pseudonormal, and restrictivelike filling patterns. Patients diagnosed with evidence of abnormal LV diastolic function (n=119) had a mean BNP concentration of 286 +/- 31 pg/mL; those in the normal LV group (n=175) had a mean BNP concentration of 33 +/- 3 pg/mL. Patients with restrictive like filling patterns on echocardiography had the highest BNP levels (408 +/- 66 pg/mL), and patients with symptoms had higher BNP levels in all diastolic filling patterns. The area under the receiver-operating characteristic curve for BNP to detect any diastolic dysfunction was 0.92 (95% CI, 0.87 to 0.95; P<0.001). A BNP value of 62 pg/mL had a sensitivity of 85%, a specificity of 83%, and an accuracy of 84% for detecting diastolic dysfunction. CONCLUSIONS A rapid assay for BNP can reliably detect the presence of diastolic abnormalities on echocardiography. In patients with normal systolic function, elevated BNP levels and diastolic filling abnormalities might help to reinforce the diagnosis diastolic dysfunction.
منابع مشابه
Cohort studies of cardiovascular disease in the Seychelles, Tanzania and Mauritius
Utility of B-natriuretic peptide in detecting diastolic dysfunction: comparison with Doppler velocity recordings. The impact of cardiac natriuretic peptide determination on the diagnosis and management of heart failure. Assessment of preoperative pro-BNP levels in patients with rheumatic heart disease with normal left ventricular function; Institute of Cardiovascular Diseases. et al. Usefulness...
متن کاملNatriuretic peptides in patients with diastolic dysfunction due to idiopathic dilated cardiomyopathy.
AIMS The degree of systolic dysfunction does not always correlate with functional impairment in patients with congestive heart failure. In contrast, diastolic dysfunction correlates well with functional impairment. In heart failure, both elevation of N-terminal proatrial natriuretic peptide and B-type natriuretic peptide are markers of a poor prognosis. METHODS We investigated 32 patients (26...
متن کاملRole of tissue Doppler imaging in assessing left ventricular diastolic dysfunction severity. Does it hold the same ability?
OBJECTIVE To validate the diagnostic capability of tissue Doppler imaging in assorting the extent of diastolic dysfunction. METHODS In this primary clinical research diagnostic study, we enrolled 70 patients with systemic hypertension presenting with shortness of breath between May 2010 to July 2010 to Salmaniya Medical Complex, Manama, Bahrain. Forty-eight patients satisfied the inclusion c...
متن کاملInfluence of pneumoperitoneum on left ventricular filling pressures and NT-proBNP levels.
BACKGROUND We recently demonstrated that pneumoperitoneum affects diastolic echocardiographic findings in healthy women scheduled for gynaecologic laparoscopy. No reports have been conducted in order to assess the echocardiographic consequences in hypertensive subjects during laparoscopic procedures. AIM The aim of this study was to evaluate Left Ventricular filling pressures in hypertensive ...
متن کاملCorrelation to NT-ProBNP and remodeling after cardiac surgery.
BACKGROUND Few data are available on diastolic function in patients with aortic stenosis (AOS) with indication of surgical treatment. A potential correlation between biomarkers and diastolic function has not been established. OBJECTIVE The aim of our study was to evaluate diastolic function in patients with AOS waiting for aortic valve replacement (AVR) echocardiographically, and to verify it...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 106 15 شماره
صفحات -
تاریخ انتشار 2002