Hip Squeaking

نویسنده

  • Christophe Chevillotte
چکیده

The aim of the study was to analyze the incidence of squeaking with ceramic-onceramic total hip arthroplasty (THA) after 10 years of follow-up and the potential complications that could occur related to this phenomenon. One hundred THAs implanted between November 1999 and December 2000 were evaluated. Incidence of squeaking was investigated clinically with a questionnaire. Implant positioning was analyzed on x-rays and computer tomography. Of the 100 THAs, 5 patients presented with squeaking. All of them were active, sporty, and heavy men. Functional scores were comparable with nonsqueaking patients. There was no malpositioning on the x-ray analysis, no wear, and no loosening. We could not demonstrate any relation between squeaking and ceramic fracture. Squeaking noise appeared at a mean of 66 months postsurgery. It appears to be an isolated phenomenon without any consequences at 10-year follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Computational Analysis of Squeaking Hip Prostheses

A ceramic-on-ceramic (CoC) hip prosthesis with clearance is modeled as a multibody dynamics system for the purpose of studying hip squeaking. A continuous contact force model provides the intrajoint forces developed at the hip joint. Friction effects due to the relative motion are also considered. A FFT analysis of the audible sounds from CoC hip acceleration is carried out to analyze hip squea...

متن کامل

Influence of prosthetic design on squeaking after ceramic-on-ceramic total hip arthroplasty.

Squeaky ceramic-on-ceramic (COC) total hips have received much recent publicity, and implant design may be implicated. We reviewed 270 consecutive COC total hip arthroplasties in 233 patients comparing 4 implant combinations representing 4 manufacturers. A cohort (n = 45) of Stryker Trident acetabular cups paired with Stryker Accolade femoral stems showed a dramatically higher incidence of "pro...

متن کامل

An estimation of the incidence of squeaking and revision surgery for squeaking in ceramic-on-ceramic total hip replacement: a meta-analysis and report from the Australian Orthopaedic Association National Joint Registry.

Squeaking arising from a ceramic-on-ceramic (CoC) total hip replacement (THR) may cause patient concern and in some cases causes patients to seek revision surgery. We performed a meta-analysis to determine the incidence of squeaking and the incidence of revision surgery for squeaking. A total of 43 studies including 16,828 CoC THR that reported squeaking, or revision for squeaking, were entered...

متن کامل

Ceramic liner fractures presenting as squeaking after primary total hip arthroplasty.

BACKGROUND Squeaking after ceramic-on-ceramic total hip arthroplasty is a relatively uncommon phenomenon. It usually does not require treatment in the absence of pain, mechanical symptoms, and/or relentless squeaking. The purpose of this investigation was to report on four patients who presented with hip pain and squeaking due to fractured ceramic liners after ceramic-on-ceramic total hip arthr...

متن کامل

Meta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients

PURPOSE The purpose of this study was to assess the squeaking incidence and risk factors after primary ceramic-on-ceramic total hip arthroplasty (THA) in Asian patients using meta-analysis. MATERIALS AND METHODS We performed a meta-analysis of published data on the squeaking incidence and risk factors from 2000 to 2013. Eight studies in Asians were analyzed for both squeaking incidence and ri...

متن کامل

The role of patient factors and implant position in squeaking of ceramic-on-ceramic total hip replacements.

We investigated factors that were thought to be associated with an increased incidence of squeaking of ceramic-on-ceramic total hip replacements. Between June 1997 and December 2008 the three senior authors implanted 2406 primary total hip replacements with a ceramic-on-ceramic bearing surface. The mean follow-up was 10.6 years. The diagnosis was primary osteoarthritis in each case, and no pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012