A cell-based bar code reader for high-throughput screening of ion channel-ligand interactions.

نویسندگان

  • Jon Sinclair
  • Johan Pihl
  • Jessica Olofsson
  • Mattias Karlsson
  • Kent Jardemark
  • Daniel T Chiu
  • Owe Orwar
چکیده

This paper presents a microfluidics-patch clamp platform for performing high-throughput screening and rapid characterization of weak-affinity ion channel-ligand interactions. This platform integrates a microfluidic chip consisting of multiple channels entering an open volume with standard patch clamp equipment. The microfluidic chip is placed on a motorized scanning stage and the method relies on the ability to scan rapidly, on the order of milliseconds, a patch-clamped cell across discrete zones of different solutions created in the open volume. Under ideal conditions, this method has the capacity to obtain kinetically resolved patch clamp measurements and dose-response curves of up to 10(3) ligand solutions in a single day.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

QPatch: the missing link between HTS and ion channel drug discovery.

The conventional patch clamp has long been considered the best approach for studying ion channel function and pharmacology. However, its low throughput has been a major hurdle to overcome for ion channel drug discovery. The recent emergence of higher throughput, automated patch clamp technology begins to break this bottleneck by providing medicinal chemists with high-quality, information-rich d...

متن کامل

Novel screening techniques for ion channel targeting drugs

Ion channels are integral membrane proteins that regulate the flux of ions across the cell membrane. They are involved in nearly all physiological processes, and malfunction of ion channels has been linked to many diseases. Until recently, high-throughput screening of ion channels was limited to indirect, e.g. fluorescence-based, readout technologies. In the past years, direct label-free biophy...

متن کامل

High-throughput screening for ion channel modulators.

Ion channels present a group of targets for major clinical indications, which have been difficult to address due to the lack of suitable rapid but biologically significant methodologies. To address the need for increased throughput in primary screening, the authors have set up a Beckman/Sagian core system to fully automate functional fluorescence-based assays that measure ion channel function. ...

متن کامل

Cellular fluorescent indicators and voltage/ion probe reader (VIPR) tools for ion channel and receptor drug discovery.

High throughput functional assays are increasingly relied upon to generate early and novel discovery leads for drug development. Ion transport proteins including channels, transporters, and pumps play central roles in cellular bioenergetics, excitability, and a multitude of other biological functions. Facile, robust methods for detecting ion transport activity in both native and heterologous sy...

متن کامل

A novel membrane potential-sensitive fluorescent dye improves cell-based assays for ion channels.

The study of ion channel-mediated changes in membrane potential using the conventional bisoxonol fluorescent dye DiBAC(4)(3) has several limitations, including a slow onset of response and multistep preparation, that limit both the fidelity of the results and the throughput of membrane potential assays. Here, we report the characterization of the FLIPR Membrane Potential Assay Kit (FMP) in cell...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 74 24  شماره 

صفحات  -

تاریخ انتشار 2002