Prospective identification of ventricular septal defects in infancy using subxiphoid two-dimensional echocardiography.

نویسندگان

  • F Z Bierman
  • K Fellows
  • R G Williams
چکیده

The objective of this study was to establish a dependable technique for imaging the interventricular septum and ventricular septal defects in infants. Subxiphoid two-dimensional echocardiograms were performed on 81 infants who were 1 day to 12 months (median 43 days) old and weighed 1.6-8.6 kg (median 3.4 kg). A short-focus, 5-MHz crystal with a 13-mm active element diameter was used in all studies. The interventricular septum was visualized in 80 of 81 infants. Defects in the membranous, atrioventricular canal, conoventricular and muscular segments of the sentum were identified using three standard transverse subxiphoid projections. All defects in the membranous and atrioventricular canal segments, as well as malalignment type conoventricular communications, were correctly identified when compared with selective angled cineangiocardiography. Only two of the three subpulmonic and four of 11 muscular defects were identified successfully. Limitations in imaging defects in the muscular septum reflected the varied morphology of these interventricular communications and the tangential orientation of the echo beam to the extreme apical and anterior segments of the muscular septum.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subxiphoid two-dimensional echocardiographic diagnosis of double-chambered right ventricle.

The echocardiographic features of 14 patients with double-chambered right ventricle are presented. Diagnosis was confirmed in 13 patients at cardiac catheterization and in one at necropsy. The ultrasonic diagnosis was based on the visualization in subxiphoid short-axis view of an anomalous muscle bundle at the lower margin of the right ventricular infundibulum; this structure was present in dia...

متن کامل

Subxiphoid cross-sectional echocardiography in infants and children with congenital heart disease.

We developed anatomically related cross-sectional echocardiographic views to image the heart from the subxiphoid area in 100 children and infants with various forms of congenital heart disease studied prospectively before cardiac catheterization. Wide-angle cross-sectional views were achieved using a mechanical sector scanner in a scan plane oriented parallel to a line between the patient's sho...

متن کامل

Left ventricular outflow tract obstruction defined by active three-dimensional echocardiography using rotational transthoracic acquisition.

A rotational data acquisition system was used to create three-dimensional images from thoracic and subxiphoid echocardiographic windows in children with various types of subaortic stenosis. Thirteen patients, ranging in age from 2 days to 17 years, were examined. Subaortic obstruction was caused by a discrete fibrous ridge in six patients, hypertrophic cardiomyopathy in two patients, subaortic ...

متن کامل

Transcatheter closure of perimembranous ventricular septal defects with Amplatzer occluder assessed by real-time three-dimensional echocardiography.

We report our initial experience in two patients using real-time three-dimensional echocardiography to assess perimembranous ventricular septal defect and device morphology and their relation with contiguous cardiac structure. Defect size and rims as well as device position and profile were displayed from the three-dimensional "en face" views. We think that real-time three-dimensional echocardi...

متن کامل

Subxiphoid cross-sectional echocardiographic imaging of the "goose-neck" deformity in endocardial cushion defect.

The cross-sectional echocardiographic demonstration of the "goose-neck" deformity is described in four patients with endocardial cushion defect. The diagnosis was confirmed in each patient by left ventricular angiocardiogram. The subxiphoid approach of cross-sectional echocardiography in diastole allowed visualization of an elongated, narrowed, and somewhat horizontally inclined configuration o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 62 4  شماره 

صفحات  -

تاریخ انتشار 1980