Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model

نویسندگان

  • Kia Homayounfar
  • Johanna Meis
  • Klaus Jung
  • Bernd Klosterhalfen
  • Thilo Sprenger
  • Lena-Christin Conradi
  • Claus Langer
  • Heinz Becker
چکیده

BACKGROUND Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. METHODS 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. RESULTS At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). CONCLUSIONS Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The comparison of thermal tissue injuries caused by ultrasonic scalpel and electrocautery use in rabbit tongue tissue.

The aim of this study compares to the increase in tissue temperature and the thermal histological effects of ultrasonic scalpel, bipolar and unipolar electrosurgery incisions in the tongue tissue of rabbits. This study evaluates the histopathological changes related to thermal change and the maximum temperature values in the peripheral tissue brought about by the incisions carried out by the th...

متن کامل

Comparing Scalpel, Electrocautery and Ultrasonic Dissector Effects: The Impact on Wound Complications and Pro-Inflammatory Cytokine Levels in Wound Fluid from Mastectomy Patients

PURPOSE Introducing the relationship between the surgical instruments used in modified radical mastectomy and wound complications is important for preventing and decreasing complications. This prospective randomized trial was designed to assess the impact of scalpel, electrocautery, and ultrasonic dissector usage on wound complications and tissue damage. METHODS Eighty-two consecutive patient...

متن کامل

A comparison of histopathologic margin assessment after steel scalpel, monopolar electrosurgery, and ultrasonic scalpel glossectomy in a rat model.

EDUCATIONAL OBJECTIVE At the conclusion of this presentation, the participants should be able to describe the tissue effects of steel scalpel, monopolar electrosurgery, and ultrasonic scalpel glossectomy with respect to histopathologic margin assessment in a rat model. OBJECTIVES Histopathologic margin assessment is important in guiding treatment and determining prognosis for squamous cell ca...

متن کامل

Effect of glossectomy technique on histopathologic assessment in a rat model.

BACKGROUND The purpose of this study was to compare the tissue effects of 3 surgical methods of glossectomy with respect to histopathologic assessment by a pathologist. METHODS The anterior tongue of 30 Sprague-Dawley rats was excised using either a steel scalpel, monopolar electrosurgery, or ultrasonic scalpel (3 groups of 10). Specimens were examined by a pathologist blinded to the surgical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012