Prospective Controlled Study of Buttock Fat Transfer Using Ultrasound and Photographic Measurements

نویسنده

  • Eric Swanson
چکیده

BACKGROUND Buttock fat transfer is now the preferred method for gluteal augmentation. However, its efficacy has not been well-documented using measurements. METHODS Twenty-five consecutive patients underwent buttock fat transfer performed by the author. Twenty-one patients returned for measurements ≥3 months after surgery (inclusion rate, 84%). A separate group of 25 patients undergoing cosmetic surgery without buttock fat transfer served as controls. All patients underwent superwet liposuction using total intravenous anesthesia and no prone positioning. A closed filtration system was used to collect the fat. Subcutaneous fat thickness was assessed using ultrasound imaging. Measurements were made on standardized photographs. The data were controlled for change in body mass index. Clinical data were also evaluated. RESULTS The mean fat volume injected per buttock was 287 mL (range, 70-550 mL). Ultrasound measurements detected a significant increase in the subcutaneous fat thickness (P ≤ 0.001), with mean increments of 0.66 cm for the right buttock and 0.86 cm for the left buttock and no significant change for control patients. The mean calculated fat retention, based on the measured surface area injected, was 66%. Photographic measurements of buttock projection revealed a significant increase in treated patients (P < 0.01) and no significant change in control patients. There were no clinical complications at either recipient or donor sites and no evidence of oily cysts on ultrasound examinations. CONCLUSIONS Photographic and ultrasound measurements, and clinical findings, confirm that buttock fat transfer effectively and safely increases buttock projection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of an anti-cellulite cream: A randomized, double-blind, placebo controlled, right-left comparison, clinical trial

Background: Cellulite is a common disease whose exact mechanism is unknown. This study was aimed to assess the safety and efficacy of an anti-cellulite preparation compared with placebo in a randomized double-blind, right-left comparison clinical trial.Methods: Twelve healthy women aged 22 to 58 years with mild to moderate cellulite on their thighs and buttocks participated in this trial. The a...

متن کامل

Fatty acid analysis of transplanted adipose tissue.

OBJECTIVE To determine whether autologously transferred human adipose tissue maintains viability in vivo for prolonged periods. DESIGN Six healthy female patients (mean age, 61.5 years; mean body mass index, 23.4 kg/m2) received autologous fat transplants from the gluteus to the nasolabial folds. Subcutaneous fat was sampled from facial and gluteal sites 4 times in 1 year. SETTING Private p...

متن کامل

Photographic facial soft tissue analysis of healthy Iranian young adults: anthropometric and angular measurements

  Background :Soft tissue profile can be widely different in various populations. Furthermore, this profile can be also continues to change throughout life. However, there are few studies that quantitatively evaluate the soft tissue profile in Iranian population. In order to determine normal reference values of facial parts in our populations, we aimed to measure standards for facial soft tissu...

متن کامل

Onm-3: Embryo Transfer Performed by a Midwifein a Prospective Randomized Study

More than 15 % of couples have infertility problems. Thecauses of infertility are equally distributed among men and women. Assisted reproduction is an option which can help many of these couples. Because of ongoing research and development of the infertility treatments the pregnancy outcome after in vitro fertilization can be increased. Embryo transfer (ET) has in the Nordic countries, by tradi...

متن کامل

Automatic classification of Non-alcoholic fatty liver using texture features from ultrasound images

Background: Accurate and early detection of non-alcoholic fatty liver, which is a major cause of chronic diseases is very important and is vital to prevent the complications associated with this disease. Ultrasound of the liver is the most common and widely performed method of diagnosing fatty liver. However, due to the low quality of ultrasound images, the need for an automatic and intelligent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016