In Vitro Analysis of Pyrogenicity and Cytotoxicity Profiles of Flex Sensors to be Used to Sense Human Joint Postures
نویسندگان
چکیده
Flex sensors can be usefully adopted as mechanical-electrical transducers to measure human joint movements, since their electrical resistance varies proportionally to the angle assumed by the joint under measure. Over time, these sensors have been investigated in terms of mechanical and electrical behavior, but no reports have detailed the possibility of their adoption not just on top but under the human skin of the joint. To this aim, our work investigated in vitro the pyrogenic potential and cytotoxicity of some commercially available flex sensors as a first step toward the necessary requirements regarding their biocompatibility, to predict possible foreign body reactions when used in vivo. Results demonstrated that some specific flex sensors satisfy such requirements.
منابع مشابه
Curvature Characterization of Flex Sensors for Human Posture Recognition
Resistive flex sensors have been increasingly used in different areas for their interesting property to change their resistance when bent. They can be employed in those systems where a joint rotation has to be measured, in particular biomedical systems, to measure human joint static and dynamic postures. In spite of their interesting properties, such as robustness, low price and long life, to d...
متن کاملA Real-time Motion Tracking Wireless System for Upper Limb Exosuit Based on Inertial Measurement Units and Flex Sensors (TECHNICAL NOTE)
This paper puts forward a real-time angular tracking (motion capture) system for a low cost upper limb exosuit based on sensor fusion; which is integrated by an elastic sleeve-mitten, two inertial measurement units (IMU), two flex sensors and a wireless communication system. The device can accurately detect the angular position of the shoulder (flexion-extension, abduction-adduction and interna...
متن کاملIn-vitro Comparison of Cytotoxicity of Two Bioactive Glasses in Micropowder and Nanopowder forms
The cytotoxicity of the biomaterials is a key issue that should be addressed prior to pre-clinical applications. This study was designed to evaluate and compare the cytotoxixity of two forms of bioactive glasses:nanopowder:andmicropowder. Human HGF1-PI53 gingival fibroblast cells were used to evaluate the cytotoxicity of 0.5, 1, 1.5, 2, 5, 10, 15 and 20 mg/mL concentrations of the two bioactive...
متن کاملIn-vitro Comparison of Cytotoxicity of Two Bioactive Glasses in Micropowder and Nanopowder forms
The cytotoxicity of the biomaterials is a key issue that should be addressed prior to pre-clinical applications. This study was designed to evaluate and compare the cytotoxixity of two forms of bioactive glasses:nanopowder:andmicropowder. Human HGF1-PI53 gingival fibroblast cells were used to evaluate the cytotoxicity of 0.5, 1, 1.5, 2, 5, 10, 15 and 20 mg/mL concentrations of the two bioactive...
متن کاملDesign and Synthesis of Novel N1-(Phenoxyethyl) Theobromine Derivatives and Evaluation of Their Cytotoxicity by in-vitro Method with Molecular Docking Study: A Laboratory Study
Background and Objectives: Cancer, one of the global health problems, has been introduced as one of the main death causes worldwide. Xanthine derivatives have been identified as effective compounds for prevention and treatment of cancer. In this study, a series of novel phenoxy ethyl theobromine derivatives were designed with N1 positioning and their cytotoxic activity was evaluated. Also, mole...
متن کامل