Part A: Biometry and Intraocular Lens Power Calculation
نویسنده
چکیده
Formulas For Intraocular lens Power calculatIon Modern cataract surgery replaces the natural lens of the eye with an intraocular lens (IOL). After surgery, the optical system of the eye will consist of two major refractive elements, the cornea and the newly inserted IOL. This two-lens system is at the basis of IOL power calculation. To facilitate calculations, both the cornea and the IOL are considered thin lenses. Although there are multiple IOL power formulas, most are similar in nature. They all require measurements of the axial length and of the corneal power. However, all these formulas require knowledge of the distance separating the two thin lenses, also known as the estimated lens position (ELP). P = n – n L – c (n/K) c In this vergence formula, P is the power of the IOL needed for emmetropia in diopters, L is the axial length in meters (all formulas adjust the equation to allow the axial length to be entered in millimeters), K is the corneal power in diopters, c is the ELP, and n is the index of refraction of the aqueous and vitreous, which is known to be 1.336. All formulas will require measurement of the axial length and of the corneal curvature. ELP is the distance between the anterior corneal surface and the implant’s optical center. This value cannot be measured before surgery and thus has to be estimated. The difference between the different formulas lies in the estimation of ELP.
منابع مشابه
Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus
Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملIntraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal.
PURPOSE Cataract development is common following retinal detachment surgery that necessitates silicone oil injection. Intraocular lens (IOL) power calculation in the presence of silicone oil is challenging for many reasons. The authors evaluated the accuracy of intraoperative biometry during cataract surgery in silicone-filled eyes. METHODS Twelve cases of cataract in eyes filled with silicon...
متن کاملAccuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation
PURPOSE To investigate the accuracy of a new optical biometer for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery. METHODS Consecutive eyes of patients undergoing cataract surgery with the same IOL model were enrolled in a prospective cohort study. Axial length (AL) and corneal power were measured with an optical biometer based on optical low-coherence interferome...
متن کاملRefractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation
PURPOSE To compare the outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery with monofocal IOL implantation. METHODS Preoperative data were obtained with the IOLMaster. Intraoperative aphakic measurements and IOL power calculations were obtained in some patients with the optiwave refract...
متن کامل