implants, should meet specific interrelated requirements for their biological, physical, mechanical, and technolog ical character [1]. Development of biocompatible materi als is enhanced by nanotechnology and plasma technolo gies [2, 3]. In particular, such technologies can be applied for creation of special porous coatings on the surface of intra tissue implants Porous coatings of this type can be used to release drugs into surrounding tissue for a pro longed time [2]. An improved technology of plasma mediated coat ing is suggested in this work to provide more homoge neous distribution of coating parameters (dispersity, par ticle and thermal flux distribution), thereby increasing the coating strength. The suggested technology is based on a systematic analysis of the physicochemical and construc tive properties of plasma coatings and can be used to reg ulate coating properties such as porosity and adhesion (Table 1). Let us consider the physicotechnological substantia tion of introducing new technological methods to con ventional coating procedures. The first technological innovation is to improve the kinematic scheme of the plasmatron by providing it with additional mobility (sweep) in the direction perpendicular to its main motion. Such sweep improves the coating parameters at the appli cation spot. The geometric scheme of coating concerning the plasmatron sweep is shown in Fig. 1. Increase in the distribution homogeneity relative to plasmatron sweep can be explained theoretically. Let the kinematic scheme of the plasmatron sweep be described using the random distribution law [4]:

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation ZrO2 ceramic coating by electrolytic plasma oxidation and study of the effect of monoclinic/tetragonal phases on the corrosion resistance of the coating

In this paper, zirconium oxide ceramics coating (ZrO2) were produced on Zircaloy-4 alloy using plasma electrolytic oxidation (PEO). Sodium silicate and Sodium aluminate based electrolyte was selected in PEO process and the effects of the concentration of Sodium aluminate (0, 2.5, 5, 7.5, and 10 g/L) on the microstructure, phase structure and the behavior of corrosion of formed coatings. In orde...

متن کامل

In vitro evaluation of apatite/wollastonite glass–ceramic nano biocoatings on 316 alloys by plasma-sprayed

Among bioactive ceramics, the apatite/wollastonite (A/W) glass ceramic, containing apatite and wollastonite crystals in the glassy matrix, has been largely studied because of good bioactivity and used in some fields of medicine, especially in orthopedics and dentistry. However, medical applications of bioceramic are limited to non-load bearing applications because of their poor mechanical prope...

متن کامل

A Review on Titanium Nitride and Titanium Carbide Single and Multilayer Coatings Deposited by Plasma Assisted Chemical Vapor Deposition

In this paper, we reviewed researches about the titanium nitride (TiN) and titanium carbide (TiC) single and multilayer coatings. These coatings were deposited by the plasma assisted chemical vapor deposition (PACVD) technique. Plasma-based technologies are used for the processing of thin films and coatings for different applications such as automobile and aerospace parts, computer disc drives,...

متن کامل

A review on the prevalent fabrication methods, microstructural, mechanical properties, and corrosion resistance of nanostructured hydroxyapatite containing bilayer and multilayer coatings used in biomedical applications

Surface treatments of the biomaterials are of great interest in many biomedical applications. Hydroxyapatite is a favorable candidate for surface modification of the implants. To date, a wide variety of methods have been developed to produce bio-active/biocompatible coatings with desirable features in order to improve the performance of the implants. This paper strives to overview the present p...

متن کامل

Effect of Plasma Electrolytic Oxidation Process as a Pretreatment on Corrosion Resistance of Polymeric Coatings Applied on Mg Alloy

In this study, Plasma Electrolytic Oxidation (PEO) at three frequencies of 500, 1000 and 3000 Hz was applied on Mg surface and the effect of PEO surface preparation on protective behavior of three types of epoxy, fusion bond epoxy (FBE) and polyurethane coatings was investigated. The microstructural and protective properties of PEO coatings were studied by SEM, potentiodynamic polarization and ...

متن کامل

Microstructure and Corrosion Performance of Silica Coatings on Aluminum Surface Prepared by Plasma Electrolysis Technique

Silica phases were precipitated on aluminum surface by potentiostatic plasma electrolysis technique. Aqueous sodium silicate solutions with different concentrations were used for this purpose. SEM, EDS, XRD, surface profiles and polarization curves were used to study coatings properties. The results showed that the growth of the silica containing phases on aluminum surface was promoted by incre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Meditsinskaia tekhnika

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012