Determination of soil amino acids by high performance liquid chromatography-electro spray ionization-mass spectrometry derivatized with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate.

نویسندگان

  • Songmei Hou
  • Hongbo He
  • Wei Zhang
  • Hongtu Xie
  • Xudong Zhang
چکیده

Determination of amino acids by mass spectrometry (MS) is an important technique to investigate soil nitrogen transformation and cycling as amino acids being the major nitrogen-containing compounds in soil organic matter. However, researchers have long faced a critical problem in coupling an efficient separation technique to a sensitive MS detection system simultaneously. In this context, we established a new method of liquid chromatography coupled to mass spectrometry based on the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) derivatization method for convenient and accurate quantification of amino acids in soil samples. Baseline separation of 17 amino acid AQC-derivatives was achieved on an XTerra(R) MS C(18) column using ammonium formate as a mobile phase modifier. The concentration of ammonium formate and the pH of the mobile phase were optimized in order to obtain sensitive MS signals. The response curves were linear over the range of 50-800 micromol L(-1) amino acids. The detection limits were 0.20-0.60 pmol microL(-1) on column and 0.07-0.24 microg g(-1) soil under the optimized conditions. The method has been applied successfully for the first time to determine amino acids in 4 types of soil samples, in which 15 amino acids were quantified by MS detector but methionine and cystine were below the detection limits. Both the recovery and the precision were satisfactory. Hence, this proposed technique shows a potential for the identification of amino acids in soil as well as tracing the transformation of soil amino acids with isotope dilution technique in nitrogen cycling investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of Glutamate, Glycine, and Alanine in Human Plasma Using Precolumn Derivatization with 6-Aminoquinolyl-N-hydroxysuccinimidyl Carbamate and High-Performance Liquid Chromatography

A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method has been validated for determining concentrations of glutamate, glycine, and alanine in human plasma. Proteins in plasma were precipitated with perchloric acid, followed by derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC). Simultaneous analysis of glutamate, glycine, and alanine is...

متن کامل

An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants

In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required...

متن کامل

Determination of isepamicin in human plasma by HPLC with fluorescence detection after derivatization using 6-aminoquinolyl-N-hydroxysuccinimidyl-carbamate.

A simple and rapid high-performance liquid chromatographic method has been developed for determination in human plasma of isepamicin (ISP), an aminoglycoside antibiotic agent. After protein precipitation and clean-up procedure to remove lipophilic contaminants, ISP is derivatized pre-column with 6-aminoquinolyl-N-hydroxysuccinimidyl-carbamate for fluorescence detection. Chromatographic separati...

متن کامل

Amino acid analysis of sub-picomolar amounts of proteins by precolumn fluorescence derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate.

Amino acid analysis (AAA) method is the most accurate methodology for absolute quantification of proteins. The conventional postcolumn method employing ninhydrin labeling of amino acids, which is adopted in automatic amino acid analyzer, is limited by low sensitivity. Therefore, a highly sensitive AAA method is required to confirm the data obtained from mass spectrometry or N-terminal sequence ...

متن کامل

Development of an in-capillary derivatization method by CE for the determination of chiral amino acids in dietary supplements and wines.

A fast in-capillary derivatization method by CE with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate was developed for the first time for the determination of amino acid enantiomers (arginine, lysine, and ornithine) in dietary supplements and wines. Because of the initial current problems due to the formation of precipitates into the capillary during the derivatization reaction, a washing step ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 80 2  شماره 

صفحات  -

تاریخ انتشار 2009