Multiple pH measurement during storage may detect bacterially contaminated platelet concentrates.

نویسندگان

  • Lynn M Barker
  • Oliver Z Nanassy
  • Michael W Reed
  • Steven J Geelhood
  • Randy D Pfalzgraf
  • Gerard A Cangelosi
  • Dirk De Korte
چکیده

BACKGROUND Bacterial contamination or platelet (PLT) metabolism can change the pH of stored PLT concentrates (PCs). Measurement of pH for quality control is currently done on a limited basis. An easy noninvasive method was developed to obtain sequential pH measurements over time, without risking contamination and/or consuming PCs. STUDY DESIGN AND METHODS The objective was to measure pH profiles of bacterially contaminated PCs over 7 days of storage. Small-volume PC storage bags with incorporated pH sensor were prepared and in vitro variables were tested using aliquots of PCs. The pH sensors were used to delineate trends associated with the deterioration of these PCs upon inoculation with 19 different bacterial strains and one yeast. RESULTS Monitoring the pH trends in real time in a noninvasive fashion, most bacterial strains were detected within 24 to 72 hours after spiking into the bag. At the time of detection, bacterial concentrations had reached levels between 1×10(3) and 1×10(8) colony-forming units/mL. Several strains had pH rebound after initial drop. Multiple noninvasive pH reads allowed bacterial detection whereas single pH reads could give false-negative results. CONCLUSIONS The noninvasive pH sensor facilitated the detection of most strains of bacterial contaminants within 3 days with no potential for sampling error.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Overview on Platelet-derived Microparticles in Platelet Concentrates: blood collection, method preparation and storage

Preparations of platelet concentrates (PCs) that are stored under blood bank conditions and used for transfusion purposes, appear to be enriched in platelet derived-microparticles (PMPs) with high coagulant activity that may change platelet efficacy and safety issues. High shear stress could cause shedding of PMPs from the platelet plasma membrane, platelet aggregation, and activation of the co...

متن کامل

تاثیر فیلتراسیون پیش از ذخیره کردن بر فعال شدن پلاکت‌ها در فراورده‌های پلاکتی

 Preparation conditions and platelet storage for transfusion may cause platelet activation, which contributes to decreased ability of stored platelet to function and survive in vivo after transfusion compared with that seen with freshly prepared platelets. Using flowcytometry, we investigated platelet membrane expression of CD62P, CD63 in platelet stored for up to 3 days under standard blood ba...

متن کامل

Evaluation of microRNAs; mir223, mir222 and mir92a levels in the Platelet-derived microparticles in the Platelet concentrates produced by Platelet Rich Plasma method during storage

Abstract Background and Objectives Platelets release microparticles containing cellular components, including microRNAs, during storage. Assessment of these microRNAs is one of the markers for evaluation of platelet storage lesions. The aim of the present study was to evaluate the level of changes in the expression of mir-223, mir-92a and mir-222 during storage in platelets prepared by platele...

متن کامل

Flow Cytometric Measurement of CD41/CD61 and CD42b Platelet Receptors and Clotting Assay of Platelet Factor 3 During Long Term-Storage of Platelet Concentrates

Background: The purpose of the present in vitro study was to evaluate the effect of long term storage of conventional platelet concentrates (PCs) on major platelet receptors CD42b and CD41/CD61 by flow cytometry method and also measuring the overall platelet procoagulant activity status using platelet factor 3 (PF3) assay. Materials and Methods: Six random units of conventional platelet conce...

متن کامل

Comparison of Diagnostic Procedures for Platelet Products Contaminated with Strains of Staphylococcus Epidermidis and Klebsiella

Abstract Background and Objective: Given that microbial contamination is the third largest cause of mortality caused blood transfusion, the examination of contamination in platelet concentrates is essential in blood transfusion centers. The purpose of this study was to achieve a rapid test for bacterial contamination of platelets concentration. Material and Methods: This laboratory ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Transfusion

دوره 50 12  شماره 

صفحات  -

تاریخ انتشار 2010