Coronal Diffusion-weighted Magnetic Resonance Imaging of the Kidney: Agreement with Axial Diffusion-weighted Magnetic Imaging in Terms of Apparent Diffusion Coefficient Values
نویسندگان
چکیده
BACKGROUND Coronal diffusion-weighted magnetic resonance imaging (DW-MRI) and apparent diffusion coefficient (ADC) values have gradually become applied (following conventional axial DW-MRI) in the renal analysis. To explore whether data obtained using coronal DW-MRI are comparable with those derived using axial DW-MRI, this preliminary study sought to assess the agreement in renal ADC values between coronal DW-MRI and axial DW-MRI. METHODS Thirty-four healthy volunteers were enrolled in the study; written consents were obtained. All subjects underwent respiratory-triggered axial and coronal DW-MRI using a 1.5-MR system with b values of 0 and 800 s/mm 2 . The signal-to-noise ratios (SNRs) of the two DW-MRI sequences were measured and statistically compared using the paired t-test. The extent of agreement of ADC values of the upper pole, mid-pole, and lower pole of the kidney; the mean ADC values of the left kidney and right kidney; and the mean ADC values of the bilateral kidneys were evaluated via calculation of intraclass correlation coefficients (ICCs) or Bland-Altman method between the two DW-MRI sequences. RESULTS The SNR of coronal DW-MR images was statistically inferior to that of axial DW-MR images (P < 0.001). The ICCs of the ADC values of each region of interest, and the mean ADC values of bilateral kidneys, between the two sequences, were greater than 0.5, and the mean ADCs of the bilateral kidneys demonstrated the highest ICC (0.869; 95% confidence interval: 0.739-0.935). In addition, 94.1% (32/34), 94.1% (32/34), and 97.1% (31/34) of the ADC bias was inside the limits of agreement in terms of the mean ADC values of the left kidneys, right kidneys, and bilateral kidneys when coronal and axial DWI-MRI were compared. CONCLUSIONS ADC values derived using coronal DW-MRI exhibited moderate-to-good agreement to those of axial DW-MRI, rendering the former an additional useful DW-MRI method, and causing the ADC values derived using the two types of DW-MRI to be comparable.
منابع مشابه
Clinical Significance of Diffusion Weighted Magnetic Resonance Imaging on Treatment Efficacy in MS Patients With Acute Attacks
Background: Despite the existence of various imaging methods, the accurate diagnosis of many neurodegenerative diseases is still controversial. The use of advanced imaging techniques, such as the diffusion weighted imaging can be help the early detection of MS and evaluation of the treatment efficacy in these patients. Materials and method: 24 MS patients with acute attack and thirty healthy s...
متن کاملThe Utility of Diffusion Weighted Magnetic Resonance Imaging in Detection of the Origin of the Brain Solid Metastatic Tumors
Background: Early diagnosis of brain tumors has significant effect on the treatment process. Brain metastatic tumors are usually diagnosed following the neurological symptoms in patients or incidentally after Computerized Tomography (CT) scan and Magnetic Resonance Imaging (MRI) requests of the brain. Objectives: Implementation of a new method for being informed about the origin of brain tumors...
متن کاملDynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors
Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...
متن کاملDiffusion-prepared fast imaging with steady-state free precession (DP-FISP): a rapid diffusion MRI technique at 7 T.
Diffusion MRI is a useful imaging technique with many clinical applications. Many diffusion MRI studies have utilized echo-planar imaging (EPI) acquisition techniques. In this study, we have developed a rapid diffusion-prepared fast imaging with steady-state free precession MRI acquisition for a preclinical 7T scanner providing diffusion-weighted images in less than 500 ms and diffusion tensor ...
متن کاملGrading of Glioma Tumors by Analysis of Minimum Apparent Diffusion Coefficient and Maximum Relative Cerebral Blood Volume
Background: Gliomas are the most common primary neoplasms of the central nervous system. Relative cerebral blood volume (rCBV) could estimate high-grade Gliomas computed with dynamic susceptibility contrast MR imaging which it is artificially lowered by contrast extravasation through a disrupted blood-brain barrier. Objectives: Our intent was to clarify the usefulness of diffusion-weighted m...
متن کامل