Automated stereotactic standardization of brain SPECT receptor data using single-photon transmission images.
نویسندگان
چکیده
UNLABELLED Intra- or intersubject registration of anatomically poorly defined SPECT data, such as in neuroreceptor imaging, is important for longitudinal or group analysis. However, accurate registration is difficult with only emission CT (ECT) data. We investigated fully automated registration using transmission CT (TCT) data as an intermediary image set. METHODS The accuracy of TCT registration was compared to that of ECT registration for four types of data: gray-matter distribution (with [99mTc]ethylcysteinate dimer (ECD)), neocortical distribution (with [123I]R91150, a highly specific 5-HT2a receptor ligand), and striatal distribution of the D2-receptor ligand (with [123I]iodobenzamide (IBZM)) and the dopamine transporter ligand (with [123I]2beta-carbomethoxy-3beta-(4-fluorophenyl)tropane (CIT)). In total, 10 datasets of the various study types were used, all collected on a Toshiba GCA9300 gamma camera with super-high-resolution fanbeam collimators and 3 x 370 MBq of 153Gd transmission sources (4-min sequential TCT scanning for receptor studies and 20-min simultaneous scanning for [99mTc]ECD studies). Per dataset, 15 random misalignments of 9 rigid-body parameters (translation, rotation, and anisotropic scaling) were conducted. All coregistrations were done twice, both to the subject's original scan and to a study-specific template. This was done manually by two independent experienced observers and with three automated voxel similarity algorithms: mutual information (M.I.), count difference (C.D.), and uniformity index (U.I.). As an outcome measure, the impact of misregistration on semiquantification for the various study types was established. RESULTS TCT matching allowed registration within 3.3 mm, 2.4 degrees, and 1.2% scaling (mean squared values for all directions) with an overall accuracy decrease in the following order: C.D. > M.I. > manual > U.I. For [99mTc]ECD and [123I]IBZM, TCT registration was as accurate as ECT registration, while it was far superior for the other receptor data types, especially for abnormal studies. The automated TCT registration accuracy corresponded to average quantification errors of 2.9% ([99mTc]ECD), 4.2% ([123I]BZM), 5.7% ([123I]R91150), and 6.1% ([123I]beta-CIT). CONCLUSION Fully automated registration through intermediary TCT images is clinically feasible, fast, and accurate. In addition to nonuniform attenuation correction, TCT scanning therefore allows coregistration for group comparisons of SPECT receptor data on a standardized or pixel-by-pixel basis.
منابع مشابه
Review of transmission scanning configurations in cardiac SPECT
The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...
متن کاملAssessment of the impact of applying attenuation correction on the accuracy of activity recovery in Tc99m-ECD brain SPECT of healthy subject using Statistical Parametric Mapping (SPM)
Introduction: Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Single Photon Emission Computed Tomography (SPECT) images. The aim of present study was to investigate the effect of attenuation correction on the detection of activation foci following statistical analysis w...
متن کاملBrain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review
Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملInfluence of photon scattering and attenuation on ROI analysis in brain perfusion single-photon emission tomographic imaging of normal subjects.
OBJECTIVE The aim of this study was to evaluate the effect of scatter and attenuation correction in region of interest (ROI) analysis in brain perfusion single-photon emission tomography (SPECT) and to assess the influence of selecting the reference area on semi-quantification. METHODS Ten normal subjects were enrolled and injected with 123I-iodoamphetamine to undergo simultaneous emission an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 42 2 شماره
صفحات -
تاریخ انتشار 2001