Influence of two different machined-collar heights on crestal bone loss.

نویسندگان

  • Mariano Herrero-Climent
  • Manuel María Romero Ruiz
  • Carmen María Díaz-Castro
  • Pedro Bullón
  • Jose Vincente Ríos-Santos
چکیده

PURPOSE The purpose of this trial was to evaluate crestal bone level changes radiographically in a standardized fashion over a period of 12 months in humans for implants with a 0.7-mm machined collar (implant type A) versus type B implants with a 1.5-mm machined collar. MATERIALS AND METHODS Twenty-five patients with multiple missing teeth in posterior sectors were randomly assigned to one of the two groups: A (0.7-mm machined-collar implants) or B (1.5-mm machined-collar implants). Changes at crestal bone level were assessed by measuring the shoulder-crest distance (SCD) on the mesial and distal aspects of each implant on customized periapical radiographs, which were taken on the day of surgery and 3, 6, and 12 months after surgery. RESULTS Eighty-one implants were included in the study. Mean SCD was 0.54 ± 0.53 mm at baseline and 1.49 ± 0.40 mm after 12 months. For 0.7-mm-collar implants, mean SCD was 1.40 ± 0.39 mm, while it was 1.56 ± 0.40 mm for 1.5-mm-collar implants. Statistically significant differences were found only between the two types of implants for distal measurements at 3 and 12 months after placement. CONCLUSION Both 0.7- and 1.5-mm machined-collar implants can be used with predictable results, as changes in peri-implant crestal bone levels are similar for both implant types and do not seem to be significant from a clinical point of view. The SCD may well depend more on the location of the abutment-implant interface than on machined-collar height.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of implant–abutment connection and positioning of the machined collar/microgap on crestal bone level changes: a systematic review

OBJECTIVES To address the following focused question: What is the impact of implant-abutment configuration and the positioning of the machined collar/microgap on crestal bone level changes? MATERIAL AND METHODS Electronic databases of the PubMed and the Web of Knowledge were searched for animal and human studies reporting on histological/radiological crestal bone level changes (CBL) at nonsub...

متن کامل

Crestal bone changes around titanium implants. Part I: A retrospective radiographic evaluation in humans comparing two non-submerged implant designs with different machined collar lengths.

BACKGROUND Experimental studies demonstrated that peri-implant crestal hard and soft tissues are significantly influenced in their apico-coronal position by the rough/smooth implant border as well as the microgap/ interface between implant and abutment/restoration. The aim of this study was to evaluate radiographically the crestal bone level changes around two types of implants, one with a 2.8 ...

متن کامل

Impact of implant–abutment connection, positioning of the machined collar/microgap, and platform switching on crestal bone level changes. Camlog Foundation Consensus Report.

OBJECTIVES The aim of this consensus meeting was to assess the impact of implant-abutment connection, positioning of the machined collar/microgap, and platform switching on crestal bone level changes. MATERIALS AND METHODS Two comprehensive systematic reviews were prepared in advance of the meeting. Consensus statements, practical recommendations, and implications for future research were bas...

متن کامل

Clinical evaluation of the stability of implants placed at different supracrestal levels

PURPOSE The aim of this study was to evaluate the stability during healing and before loading of implants placed at two different supracrestal levels according to their collar texture. MATERIALS AND METHODS This retrospective study included patients who received posterior implants with the same macro design. Implants with a machined collar were placed 0.3 mm above the crestal bone (M group), ...

متن کامل

Clinical evaluation of laser microtexturing for soft tissue and bone attachment to dental implants.

INTRODUCTION A tapered dental implant (Laser-Lok [LL] surface treatment) with a 2 mm wide collar, that has been laser micromachined in the lower 1.5 mm to preferentially accomplish bone and connective tissue attachment while inhibiting epithelial downgrowth, was evaluated in a prospective, controlled, multicenter clinical trial. MATERIALS Data are reported at measurement periods from 1 to 37 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 2014