Construction And Demonstration Of A Tandem Mass Spectrometer Based Instrument For Cold Ion Spectroscopy

نویسندگان

  • James Gerhardt Redwine
  • Scott A. McLuckey
  • Timothy S. Zwier
  • Lyudmila Slipchenko
  • R. G. Cooks
چکیده

Redwine, James Gerhardt. Ph.D., Purdue University, December 2013. Construction and Demonstration of a Tandem Mass Spectrometer Based Instrument for Cold Ion Spectroscopy. Major Professors: Scott McLuckey & Timothy Zwier. A new instrument incorporating ion trap based tandem mass spectrometry and cold ion UV and UV-IR double resonance spectroscopy has been developed at Purdue University for the study of gas phase, biologically relevant ions. The instrument incorporates multiple quadrupole linear ion trap mass analyzers to prepare and isolate the precursor ions as well as to analyze the resultant photofragments. A 22-pole ion trap cooled to 5 K via a closed cycle helium cryostat is used to cool the ions for spectroscopic interrogation. Results show the vibrational and rotational temperature of a wide assortment of ions to be 12±2 K. The capabilities of the instrument are confirmed using the protonated amino acid tyrosine (Tyr), following precedent established in the literature. The UV spectrum shows 12±2 K ion temperatures and signal to noise comparable to previous studies presented in the literature. A novel mode of UV photofragment spectroscopy is presented which allows for the observation of all photofragments, whereas previous methods observe the fragmentation of a single mass channel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

A novel high-capacity ion trap-quadrupole tandem mass spectrometer.

We describe a prototype tandem mass spectrometer that is designed to increase the efficiency of linked-scan analyses by >100-fold over conventional linked-scan instruments. The key element of the mass spectrometer is a novel high ion capacity ion trap, combined in tandem configuration with a quadrupole collision cell and a quadrupole mass analyzer (i.e. a TrapqQ configuration). This ion trap ca...

متن کامل

Development of a low-temperature photoelectron spectroscopy instrument using an electrospray ion source and a cryogenically controlled ion trap.

The ability to control ion temperatures is critical for gas phase spectroscopy and has been a challenge in chemical physics. A low-temperature photoelectron spectroscopy instrument has been developed for the investigation of complex anions in the gas phase, including multiply charged anions, solvated species, and biological molecules. The new apparatus consists of an electrospray ionization sou...

متن کامل

Automatic identification of proteins with a MALDI-quadrupole ion trap mass spectrometer.

A matrix-assisted laser desorption/ionization (MALDI) ion trap mass spectrometer of new design is described. The instrument is based on a commercial Finnegan LCQ ion trap mass spectrometer to which we have added a MALDI ion source that incorporates a sample stage constructed from a compact disk and a new ion transmission interface. The ion interface contains a quadrupole ion guide installed bet...

متن کامل

Construction and performance test of a multiplexed multistage (MS(n)) time-of-flight mass spectrometer.

A time-of-flight mass spectrometer equipped with two reflectrons was constructed for multiplexed photodissociation tandem mass spectrometry of peptide ions generated by matrix-assisted laser desorption ionization. A linear reflectron was used for high-resolution selection of a precursor ion while a quadratic reflectron was used for product ion analysis. With the photoexcitation of a precursor i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015