Owing to its intrinsic characteristics, spatiotemporally encoded (SPEN) imaging is less sensitive to adverse effects due to field inhomogeneity in comparison with echo planar imaging, a feature highly desired for functional, diffusion, and real-time MRI. However, the quality of images obtained with SPEN MRI is still degraded by geometric distortions when field inhomogeneity exists. In this study, a single-shot biaxial SPEN (bi-SPEN) pulse sequence is implemented, utilizing a 90° and a 180° chirp pulse incorporated with two orthogonal gradients. A referenceless geometric-distortion correction based on the single-shot bi-SPEN sequence is then proposed. The distorted image acquired with the single-shot bi-SPEN sequence is corrected by iterative super-resolved reconstruction involving the field gradients estimated from a field map, which in turn is obtained from its own super-resolved data after a phase-unwrapping procedure without additional scans. In addition, the distortion correction method is applied to improve the quality of the multiple region-of-interest images obtained with single-shot bi-SPEN sequence.
منابع مشابه
Referenceless reconstruction of spatiotemporally encoded imaging data: principles and applications to real-time MRI.
PURPOSE Ultrafast sequences based on "Hybrid" spatiotemporal encoding (SPEN) replace echo-planar imaging's phase encoding "blips," while retaining a k-space readout acquisition. Hardware imperfections during acquisition may lead to ghosts and striped artifacts along the SPEN dimension; akin to echo-planar imaging's Nyquist ghosts, but weaker. A referenceless method to eliminate these artifacts ...
متن کاملUltrafast in vivo diffusion imaging of stroke at 21.1 T by spatiotemporal encoding.
PURPOSE This study quantifies in vivo ischemic stroke brain injuries in rats using ultrahigh-field single-scan MRI methods to assess variations in apparent diffusion coefficients (ADCs). METHODS Magnitude and diffusion-weighted spatiotemporally encoded imaging sequences were implemented on a 21.1 T imaging system, and compared with spin-echo and echo-planar imaging diffusion-weighted imaging ...
متن کاملPRF based MR-Thermometry on Abdominal Organs: A pragmatic comparison of referenceless vs multi-baseline
Introduction Reliable temperature and thermal-dose measurements using PRF based MR-thermometry for MR-guided ablation therapy on abdominal organs are complicated by the fact that the target moves through an inhomogeneous and time-variant magnetic field. Two correction approaches emerged recently as the most promising candidates to allow continuous real-time MR-thermometry under free-breathing c...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 105 شماره
صفحات -
تاریخ انتشار 2015