Evaluation of usefulness of scintigraphic imaging in diagnosis of intrathecal drug delivery system malfunction – a preliminary report

نویسندگان

  • Jacek Teodorczyk
  • Tomasz Szmuda
  • Mariusz Siemiński
  • Piotr Lass
  • Paweł Słoniewski
چکیده

BACKGROUND Implantable intrathecal drug delivery systems (IDDS) are basic tool enabling chronic intrathecal pharmacotherapy. Lack of expected clinical results of IDDS therapy necessitates search for the cause with the help of diagnostic imaging methods among other things. Beside radiological techniques, it is also possible to visually assess IDDS systems by nuclear medicine methods. In this study we assess utility of radioisotopic methods in differential diagnosis of failure of therapy with IDDS systems. MATERIAL/METHODS Scintigraphic studies were performed in selected patients with neurological diseases associated with spasticity, who had IDDS system implanted and were unable to maintain satisfying clinical effect of inrathecally infused baclofen. After emptying the IDDS system of the drug, radiotracer (99mTc-DTPA) solution was injected into the pump reservoir. Subsequently, a series of scintigraphic images was registered, demonstrating passage and distribution of the infused radiotracer. RESULTS In all investigated cases, scintigraphic study resulted in acquiring relevant additional diagnostic information. Normal or disrupted distribution of radiotracer in spinal canal allowed for a diagnosis drug resistance or demonstrated presence of arachnoid adhesions respectively. Early appearance of radiotracer in blood was considered a proof of leak. Our examinations had decisive influence on further patient treatment, allowing for diagnosis of drug resistance in one patient or complication related to IDDS system in three other cases including breakage of a catheter, pump malfunction and arachnoid adhesions. CONCLUSIONS Scintigraphic methods carry significant amount of information facilitating final diagnosis of the cause of IDDS therapy failure. They should become an important element complementing the diagnostic strategy in patients with suspected failure of intrathecal drug administration systems. Interpretation of radioisotopic studies, since they are purely functional, must be performed in strict relation to clinical data and radiological examinations as they carry indispensable, basic information regarding morphology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tc-99m-Pertechnetate in evaluation of meckel's diverticulum [Persian]

Meckel's diverticulum is a common congenital disorder which may result in Gl bleeding. For definite diagnosis before surgery, radiographic procedures such as small intestine barium studies are not greatly successful; on the other hand Tc-99m-Pertechnetate imaging is a physiologic and noninvasive method with high sensitivity and specificity. In this report, three patients with rectorrhagia...

متن کامل

Controlled-Release Low Density Effervescent Floating Matrix Tablets of Risperidone: Development, Optimization, in vitro-in vivo Evaluation in Healthy Human Volunteers and Determination of Dissolution Equivalency

The main objective of the present study was to formulate gastroretentive effervescent sustained release drug delivery systems of risperidone floating tablets with the help of Methocel® K15, Ethocel® standard 7FP premium, Eudragit ® RS100 sustained release polymers to improve its safety profile, bioavailability and patient compliance. Risperidone floating tablets were formulated by wet granulati...

متن کامل

Design and Comparative Evaluation of In-vitro Drug Release, Pharmacokinetics and Gamma Scintigraphic Analysis of Controlled Release Tablets Using Novel pH Sensitive Starch and Modified Starchacrylate Graft Copolymer Matrices

The present investigation deals with the development of controlled release tablets of salbutamol sulphate using graft copolymers (St-g-PMMA and Ast-g-PMMA) of starch and acetylated starch. Drug excipient compatibility was spectroscopically analyzed via FT-IR, which confirmed no interaction between drug and other excipients. Formulations were evaluated for physical characteristics like hardness,...

متن کامل

Design and Comparative Evaluation of In-vitro Drug Release, Pharmacokinetics and Gamma Scintigraphic Analysis of Controlled Release Tablets Using Novel pH Sensitive Starch and Modified Starchacrylate Graft Copolymer Matrices

The present investigation deals with the development of controlled release tablets of salbutamol sulphate using graft copolymers (St-g-PMMA and Ast-g-PMMA) of starch and acetylated starch. Drug excipient compatibility was spectroscopically analyzed via FT-IR, which confirmed no interaction between drug and other excipients. Formulations were evaluated for physical characteristics like hardness,...

متن کامل

18F-FDG PET/CT usefulness vs Tc99m-Tetrofosmin in the assessment of malignant brain gliomas: Report of two cases

Gliomas account for almost 80% of primary malignant brain tumors in adults. Magnetic Resonance imaging (MRI) is still the gold standard for diagnosis of brain tumors and brain 99mTc-tetrofosmin Single Photon Emission Computed Tomography (99mTc-tetrofosmin-SPECT) has been established as a useful tool for their evaluation. Fluorine-18–2-fluoro-2-deoxy-d-glucose positron emi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 78  شماره 

صفحات  -

تاریخ انتشار 2013