The multifocal visual evoked potential: An objective measure of visual fields?

نویسندگان

  • William Seiple
  • Karen Holopigian
  • Colleen Clemens
  • Vivienne C. Greenstein
  • Donald C. Hood
چکیده

We examined the effects of inter-modal attention and mental arithmetic on Humphrey visual field sensitivity and multifocal visual evoked potential (mfVEP) amplitude. Four normally sighted subjects (ages ranging from 24 to 58 years) participated in this study. Monocular visual field sensitivity was measured under two conditions: (1) standard testing condition and (2) while the subject performed a Paced Auditory Serial Addition Task (PASAT). Monocular mfVEPs were recorded in response to a 60-sector stimulus. The checkerboard pattern in each sector was contrast reversed according to a binary m-sequence. mfVEPs were recorded under two conditions: (1) standard testing conditions and (2) while the subject performed a PASAT. We found that, when compared to the no-task condition, all subjects had locations of significantly reduced Humphrey visual field sensitivities when performing the PASAT. In contrast, there were no significant decreases in mfVEP amplitude in any sector for any of the subjects while performing the PASAT. Our findings indicate that divided attention and ongoing mental processes did not affect the mfVEP. Therefore, the mfVEP provides an objective measure of visual field function that may be useful for some patients with unreliable automated static perimetry results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Machine learning based Visual Evoked Potential (VEP) Signals Recognition

Introduction: Visual evoked potentials contain certain diagnostic information which have proved to be of importance in the visual systems functional integrity. Due to substantial decrease of amplitude in extra macular stimulation in commonly used pattern VEPs, differentiating normal and abnormal signals can prove to be quite an obstacle. Due to developments of use of machine l...

متن کامل

Comparison of visual evoked potential changes in patients with alzheimer, vascular dementia and minimal cognitive Impairment with healthy people: a case-control study

Background: Alzheimer dementia as the most common cause of dementia is a chronic, progressive, irreversible and incurable disease. The second most common cause of dementia after Alzheimer is vascular dementia. One of the systems involved in dementia is the visuospatial system and visual evoked potential (VEP) can be one of the diagnostic methods for this disease. Therefore, the present study ai...

متن کامل

An interocular comparison of the multifocal VEP: a possible technique for detecting local damage to the optic nerve.

PURPOSE To develop a quantitative measure of local damage to the ganglion cells/optic nerve based on an interocular comparison of multifocal visual evoked potentials (mVEP). METHODS Multifocal VEPs were recorded from both eyes of six normal subjects and four patients; each eye was stimulated separately. Two of the patients had glaucoma, one had ischemic optic neuropathy, and one had unilatera...

متن کامل

Abnormalitites of Visual Evoked Potential in Migraine Patients

Background: Visual evoked potential (VEP) is regarded as a useful, reliable and non-invasive technique for the diagnosis of lesions in the optic pathway.  This technique was used to investigate visual function in migraine.   Materials and Methods: 53 migraine patients (27 migraine cases with aura and 26 common migraine cases) and 55 controls were prospectively enrolled in this study.  Visual ev...

متن کامل

Multifocal visual evoked potential in nonorganic visual field loss.

OBJECTIVE To evaluate the use of multifocal visual evoked potentials in the diagnosis of nonorganic visual field loss. METHODS Five patients with unexplained visual field loss underwent full neuro-ophthalmic examination, Humphrey visual field testing, and multifocal visual evoked potential testing using the Accumap objective perimeter (ObjectiVision Pty Ltd, Sydney, Australia). RESULTS In a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2005