High Resolution Diffusion Tensor Imaging of the Human Brain at 7T

نویسندگان

  • Ralf Lützkendorf
  • Sebastian Baecke
  • Johannes Mallow
  • Tim Herrmann
  • Jörg Stadler
  • Claus Tempelmann
  • Thomas Trantzschel
  • Johannes Bernarding
چکیده

Magnetic resonance imaging (MRI) at 7T provides higher signal-to-noise ratio (SNR) which enables high-resolution functional and anatomic MRI. There is also an increased demand for high-resolution diffusion tensor imaging (DTI) providing important information about cell physiology and neuronal connectivity. DTI may also profit from higher SNR as diffusion-weighting reduces the signal exponentially. But the potential SNR gain in ultra-high field (UHF) DTI is counterbalanced mainly by shortened T 2 relaxation times of brain tissue, increased signal inhomogeneities, and coil parameter dependencies for parallel imaging. High resolution DTI (1.15/1.15/3.0 mm 3) was performed at 3T and 7T. Parallel imaging (GRAPPA, reconstruction factor 3) and data averaging was required to reduce image distortions, inhomogeneous signal distribution, and increase SNR. This allowed calculating high resolution Diffusion tensor and fractional anisotropy maps. In temporal and basal regions the reduced signal-to-noise ratio rendered the calculated parameter maps less reliable. A simulation of the distribution of the excitation radio frequency (RF) field at 7T in a human voxel model revealed that the inhomogeneities of brain tissue leads to inhomogeneous excitation which is a major cause for observed signal voids. High resolution DTI is therefore feasible at 7T with an image quality comparable or superior to 3T DTI. Main advantage for 7T DTI is combining DTI with anatomic and functional MRI acquired at 7T on the same MR scanner thereby reducing registration errors.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Diffusion Tensor Imaging of White Matter Microstructure in Dog Brain at 7T

The purpose of this study is to develop a noninvasive quantitative imaging scheme to assess the functional microanatomy of dog brain using high resolution diffusion tensor imaging (DTI) at 7-Tesla (T) magnetic resonance imaging (MRI) scanner. Diffusion weighted images (DWIs) along 25 diffusion-encoding directions, combined with T2 weighted images, were acquired using the standard spin-echo diff...

متن کامل

In Vivo Human Brain Diffusion Tensor Imaging (DTI) at 3T and 7 T

Introduction: Higher B0 fields are expected to optimize fiber tracking and to increase the signal-to-noise ratio which should lead to higher spatial resolution of DTI [1,2]. However, at high fields B1 inhomogeneities are strong and result in sever distortions and signal voids in DTI. The B1 inhomogeneity results in ill-defined pulse angles that vary considerably over the probe volume. Parallel ...

متن کامل

Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter

Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...

متن کامل

Diffusion Tensor Imaging at 7T: Expectations vs. Reality Check

INTRODUCTION Diffusion tensor imaging (DTI or HARDI) offers the unique possibility to detect brain microstructure in vivo. However, diffusion weighting requires strong and long gradient pulses that, in addition to strong T2 weighting, reduce the signal significantly to encode the directional information. Therefore, DTI is notoriously SNR hungry and the use of very high field strength has been p...

متن کامل

Diffusion imaging in humans at 7T using readout-segmented EPI and GRAPPA.

Anatomical MRI studies at 7T have demonstrated the ability to provide high-quality images of human tissue in vivo. However, diffusion-weighted imaging at 7T is limited by the increased level of artifact associated with standard, single-shot, echo-planar imaging, even when parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA) are used to reduce ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012