Comparison of the Airtraq laryngoscope and the GlideScope for double-lumen tube intubation in patients with predicted normal airways: a prospective randomized trial
نویسندگان
چکیده
BACKGROUND The Airtraq laryngoscope and the GlideScope are commonly used in many airway scenarios. However, their features have not been fully described for double-lumen tube intubation. A prospective randomized study was designed to compare their intubation performances in thoracic surgery patients. METHODS Seventy ASA physical status I and II patients with predicted normal airway were scheduled for thoracic surgeries with double-lumen tube intubation. They were randomly assigned to one of two groups and intubated with either the Airtraq laryngoscope (group A, n = 35) or the GlideScope (group G, n = 35). Airway assessments were performed prior to anesthesia, and all patients were induced with a standard anesthetic regimen. The Cormack-Lehane grades were initially evaluated with a Macintosh laryngoscope and subsequently with the group-specific laryngoscope before intubation. Intubation time was recorded as the primary outcome. The Cormack-Lehane grade, the success of the first intubation attempt, the intubation difficulty scales and ease of tube advancement were noted. Hemodynamic variables during intubation and incidence of post-operative sore throat were documented as well. RESULTS The intubation time of group A was shorter than that of group G (36.6 ± 20.2 s vs. 54.6 ± 25.7 s, p = 0.002). The Cormack-Lehane grade (I/II/III/IV) was significantly better in group A (33/2/0/0 vs. 28/7/0/0, p = 0.042). The mean arterial pressure and heart rate rose to higher levels during intubation with the GlideScope than with the Airtraq laryngoscope. The success of the first intubation attempt and the intubation difficulty scales were comparable between the two groups. The numbers of patients who experienced postoperative sore throat were similar (6 vs. 8) in the two groups. CONCLUSIONS Compared with the GlideScope, the specially designed Airtraq laryngoscope might be more suitable for double-lumen tube intubations in patients with predicted normal airway. TRIAL REGISTRATION www.chictr.org Identifier: ChiCTR-TRC-11001628.
منابع مشابه
Haemodynamic response at double lumen bronchial tube placement - Airtraq vs. MacIntosh laryngoscope, a randomised controlled trial
INTRODUCTION Tracheal intubation causes a haemodynamic response that might be harmful for patients. The Airtraq® laryngoscope has been shown to decrease the haemodynamic response to single-lumen tube intubation. We hypothesised that double-lumen bronchial tube placement with the Double-lumen Airtraq® laryngoscope would cause a reduced haemodynamic response and decreased catecholamine release co...
متن کاملComparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملMcGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation
BACKGROUND Many studies have shown Airtraq videolaryngoscope provided faster tracheal intubation and a higher success rate than other videolaryngoscopes. Recently, different types of videolaryngoscopes have been reported for use in double-lumen tube (DLT) intubation. However, the advantages and disadvantages between them remain undetermined for DLT intubation. In this study, we compared the Air...
متن کاملIncidence and severity of postoperative sore throat: a randomized comparison of Glidescope with Macintosh laryngoscope
BACKGROUND Postoperative sore throat (POST) is a common problem following endotracheal (ET) intubation during general anesthesia. The objective was to compare the incidence and severity of POST during routine intubation with Glidescope (GL) and Macintosh laryngoscope (MCL). METHODS One hundred forty adult patients ASA I and II with normal airway, scheduled to undergo elective surgery under GA...
متن کاملمقایسه میزان موفقیت لوله گذاری تراشه بعد از آموزش با دو روش گلایدسکوپ و لارنگوسکوپ
Background: Tracheal intubation is one of the most essential skills employed by all healthcare providers, nevertheless novice intubators turn out to be less successful when they initially perform the intubation. Video- laryngoscopes (GlideScopes) are novel instruments able to increase the success rate of tracheal intubation training. The aim of this study was to compare the success rate of trac...
متن کامل