Does carotid stent cell design matter?
نویسندگان
چکیده
BACKGROUND AND PURPOSE Carotid stent cell design has recently been suggested to be a determinant of periprocedural and early postprocedural neurologic complications. We investigated the impact of closed- versus open-cell stent design on neurologic adverse events and mortality after carotid artery stenting. METHODS We studied 1684 consecutive patients (1010 asymptomatic, 674 symptomatic) from 10 European centers who underwent carotid artery stenting with either closed-cell (n=859, 51%) or open-cell (n=825, 49%) design stents. Rates of transient ischemic attack, stroke, and death on the day of the procedure (acute events) and from day 1 to day 30 after the procedure (subacute events) were analyzed (95% CIs). RESULTS Combined transient ischemic attack, stroke, or death rates, and stroke or death rates within 30 days of treatment were 6.1% (95% CI, 5.0 to 7.2) and 3.1% (95% CI, 2.3 to 3.9) for the closed-cell design versus 4.1% (95% CI, 3.2 to 5.0) and 2.4% (95% CI, 1.7 to 3.1) for the open-cell design stents (P=0.077, P=0.38), respectively, without significant differences in asymptomatic and symptomatic patients. By propensity-score-adjusted multivariable analysis, the open-cell carotid stent design was not associated with a differential risk for combined acute and subacute neurologic complications compared with closed-cell stents (adjusted odds ratio=0.84, P=0.53). When analyzed separately, the risk for acute events on the day of the procedure (adjusted odds ratio=0.83, P=0.57) and the risk for subacute events at days 1 to 30 (adjusted odds ratio=1.61, P=0.51) also were not significantly different between the groups. CONCLUSIONS Current data do not support the superiority of a specific carotid stent cell design with respect to neurologic complications, stroke, and mortality risk.
منابع مشابه
Comparison of closed-cell and hybrid-cell stent designs in carotid artery stenting: clinical and procedural outcomes
INTRODUCTION Carotid artery stenting (CAS) is a promising alternative to surgery in high-risk patients. However, the impact of stent cell design on outcomes in CAS is a matter of continued debate. AIM To compare the periprocedural and clinical outcomes of different stent designs for CAS with distal protection devices. MATERIAL AND METHODS All CAS procedures with both closed- and hybrid-cell...
متن کاملImpact of carotid stent cell design on vessel scaffolding: a case study comparing experimental investigation and numerical simulations.
PURPOSE To quantitatively evaluate the impact of carotid stent cell design on vessel scaffolding by using patient-specific finite element analysis of carotid artery stenting (CAS). METHODS The study was organized in 2 parts: (1) validation of a patient-specific finite element analysis of CAS and (2) evaluation of vessel scaffolding. Micro-computed tomography (CT) images of an open-cell stent ...
متن کاملDelayed Cerebral Infarction due to Stent Folding Deformation Following Carotid Artery Stenting
We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established...
متن کاملStent "concertina:" stent design does matter.
The development of modern coronary stent platforms has transformed the landscape of interventional cardiology. Contemporary coronary stents are much more deliverable than older-generation stents. However, longitudinal deformation has emerged as a "new" complication in modern coronary stent platforms. Although most reported cases of longitudinal stent deformation involve mechanical or technical ...
متن کاملCarotid artery stenting simulation: from patient-specific images to finite element analysis.
The outcome of carotid artery stenting (CAS) depends on a proper selection of patients and devices, requiring dedicated tools able to relate the device features with the target vessel. In the present study, we use finite element analysis to evaluate the performance of three self-expanding stent designs (laser-cut open-cell, laser-cut closed-cell, braided closed-cell) in a carotid artery (CA). W...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 39 3 شماره
صفحات -
تاریخ انتشار 2008