Erratum for "Reliability and Application Variability of a Commercially Available Infrared Videonystagmography Unit".

نویسندگان

  • Amanda Gerling
  • Szu-Yun Leu
  • Andrew J Morton
  • Julio Echegoyen
  • Angele Nalbandian
  • Robert W Lingua
چکیده

PURPOSE Nystagmus is a condition of involuntary eye movement. The causes for nystagmus may be congenital, idiopathic, or acquired. Considerable debate exists on the therapeutic potential of various surgical techniques. Currently, there are neither standardized protocols nor devices to record quantitative data on patients with clinical nystagmus undergoing various procedures at multiple centers to facilitate randomized prospective clinical trials. METHODS The authors evaluated the reliability and variability of a commercially available infrared videonystagmography unit by recording eye movement waveforms elicited from normal volunteers (n = 117, 13 patients, 9 trials) by different examiners (A, B, and C). Five movement characteristics were examined, including saccadic latency, velocity and precision, and pursuit gain and velocity. RESULTS The overall test/retest variability was low, where the median coefficient of variation of the three testers for all five eye movement categories was less than 15%, and less than 10% of the coefficients of variation calculated were more than 20%. However, there was a significant difference in interobserver variability for all outcomes, except saccade latency. CONCLUSIONS The between-tester analysis was found to have greater variability than the test/retest reliability analysis. Future studies at multiple sites using videonystagmography measurements should aim to have each patient repeatedly tested by the same tester. In anticipation of multicenter, randomized, prospective clinical trials of surgical procedures for nystagmus, standardized protocols for nystagmographic data collection and analysis must be validated both within and among participating centers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preoperative Sterilization Preparation of the Shoulder: A Comparative Study Evaluating Gauze Sponge and Commercially Available Applicator Prep Stick

Background: Surgical site infection (SSI) remains a concern in shoulder surgery, especially during arthroplasty. Whilemany studies have explored the characteristics and efficacy of different sterilizing solutions, no study has evaluated themethod of application. The purpose of this study was to compare two popular pre-surgical preparatory applications (two4 x 4 cm gauze sponges and applicator s...

متن کامل

Interobserver Variability of Radiographic Assessment using a Mobile Messaging Application as a Teleconsultation Tool

Background: To examine whether interobserver reliability, decision-making, and confidence in decision-making in thetreatment of distal radius fractures changes if radiographs are viewed on a messenger application on a mobile phonecompared to a standard DICOM viewer.Methods: Radiographs of distal radius fractures were presented to surgeons on either a smart phone using a mobilemessenger applicat...

متن کامل

بررسی اثر ناخالصی +2Cu برطیف گرمالیانی LiF (Mg, Cu, P)

Thermoluminescence TL materials LiF(Mg,Cu2+) and LiF(Cu2+) were produced in powder. Their 3D emission spectra were investigated and compared to the commercially available LiF(Mg,Cu2+,P) and (LiF(Mg,Ti) TL materials. Emission spectrum of LiF(Mg,Cu2+) represents a peak maximum at 450 nm with a wide shoulder ranging from 520 nm to infrared area. Emission peak of LiF(Cu2+) is situated at 380 nm and...

متن کامل

Optimal Sizing of a Reliable Hydrogen-based Stand-alone Wind-Fuel Cell System

A hybrid wind/ fuel cell generation system is designed to supply power demand. The aim of this design is to minimize the total cost of the hybrid system over an expected 20 years of operation. The optimization problem is solved aimed at providing a reliable supply for the consumer’s demand. The system consists of fuel cells, some wind units, some electrolyzers, a reformer, an anaerobic reactor ...

متن کامل

Erratum to: Application of queuing theory in inventory systems with substitution flexibility

Due to a processing error, the order of authors was incorrect. The correct order of authors is given below. 1. S. M. Seyedhoseini 2. Reza Rashid 3. Erfan Zangeneh 4. Iman Kamalpour

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pediatric ophthalmology and strabismus

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 2015