Implant design influences patient outcome after total knee arthroplasty: a prospective double-blind randomised controlled trial.

نویسندگان

  • D F Hamilton
  • R Burnett
  • J T Patton
  • C R Howie
  • M Moran
  • A H R W Simpson
  • P Gaston
چکیده

Total knee arthroplasty (TKA) is an established and successful procedure. However, the design of prostheses continues to be modified in an attempt to optimise the functional outcome of the patient. The aim of this study was to determine if patient outcome after TKA was influenced by the design of the prosthesis used. A total of 212 patients (mean age 69; 43 to 92; 131 female (62%), 81 male (32%)) were enrolled in a single centre double-blind trial and randomised to receive either a Kinemax (group 1) or a Triathlon (group 2) TKA. Patients were assessed pre-operatively, at six weeks, six months, one year and three years after surgery. The outcome assessments used were the Oxford Knee Score; range of movement; pain numerical rating scales; lower limb power output; timed functional assessment battery and a satisfaction survey. Data were assessed incorporating change over all assessment time points, using repeated measures analysis of variance longitudinal mixed models. Implant group 2 showed a significantly greater range of movement (p = 0.009), greater lower limb power output (p = 0.026) and reduced report of 'worst daily pain' (p = 0.003) over the three years of follow-up. Differences in Oxford Knee Score (p = 0.09), report of 'average daily pain' (p = 0.57) and timed functional performance tasks (p = 0.23) did not reach statistical significance. Satisfaction with outcome was significantly better in group 2 (p = 0.001). These results suggest that patient outcome after TKA can be influenced by the prosthesis used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components.

Modifications in the design of knee replacements have been proposed in order to maximise flexion. We performed a prospective double-blind randomised controlled trial to compare the functional outcome, including maximum knee flexion, in patients receiving either a standard or a high flexion version of the NexGen legacy posterior stabilised total knee replacement. A total of 56 patients, half of ...

متن کامل

One Year After Navigated Total Knee Replacement, No Clinically Relevant Difference Found Between Fixed Bearing and Mobile Bearing Knee Replacement in a Double-Blind Randomized Controlled Trial

BACKGROUND The mobile bearing designs have not yet been shown to improve clinical outcome of total knee arthroplasty (TKA). In this prospective randomized study, we compared the short-term clinical results of a mobile bearing implant with those of the fixed bearing version of the same implant. METHODS We randomized 100 knees into two double-blind groups who received either the fixed (FB, 52 k...

متن کامل

The effect of triclosan coated sutures on rate of Surgical Site Infection after hip and knee replacement: a protocol for a double-blind randomised controlled trial

BACKGROUND 187,000 hip and knee joint replacements are performed every year in the National Health Service (NHS). One of the commonest complications is surgical site infection (SSI), and this represents a significant burden in terms of patient morbidity, mortality and cost to health services around the world. The aim of this randomised controlled trial (RCT) is to determine if the addition of t...

متن کامل

COmmunity-based Rehabilitation after Knee Arthroplasty (CORKA): study protocol for a randomised controlled trial

BACKGROUND The number of knee arthroplasties performed each year is steadily increasing. Although the outcome is generally favourable, up to 15 % fail to achieve a satisfactory clinical outcome which may indicate that the existing model of rehabilitation after surgery may not be the most efficacious. Given the increasing number of knee arthroplasties, the relative limited physiotherapy resource...

متن کامل

The impact of including corticosteroid in a periarticular injection for pain control after total knee arthroplasty: a double-blind randomised controlled trial.

UNLABELLED There is conflicting evidence about the benefit of using corticosteroid in periarticular injections for pain relief after total knee arthroplasty (TKA). We carried out a double-blinded, randomised controlled trial to assess the efficacy of using corticosteroid in a periarticular injection to control pain after TKA. A total of 77 patients, 67 women and ten men, with a mean age of 74 y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The bone & joint journal

دوره 97-B 1  شماره 

صفحات  -

تاریخ انتشار 2015