Frequency-dependent neural activity, CBF, and BOLD fMRI to somatosensory stimuli in isoflurane-anesthetized rats
نویسندگان
چکیده
Inhalation anesthetics (e.g. isoflurane) are preferable for longitudinal fMRI experiments in the same animals. We previously implemented isoflurane anesthesia for rodent forepaw stimulation studies, and optimized the stimulus parameters with short stimuli (1-3-s long stimulation with ten electric pulses). These parameters, however, may not be applicable for long periods of stimulation because repetitive stimuli induce neural adaptation. Here we evaluated frequency-dependent responses (pulse width of 1.0 ms and current of 1.5 mA) for 30-s long stimulation under 1.3-1.5% isoflurane anesthesia. The cerebral blood flow (CBF) response (using laser Doppler flowmetry: CBF(LDF)) and field potential (FP) changes were simultaneously measured for nine stimulus frequencies (1-24 Hz). CBF (using arterial spin labeling: CBF(ASL)) and blood oxygenation level dependent (BOLD) fMRI responses were measured at 9.4 T for four stimulus frequencies (1.5-12 Hz). Higher stimulus frequencies (12-24 Hz) produced a larger FP per unit time initially, but decreased more rapidly later due to neural adaptation effects. On the other hand, lower stimulus frequencies (1-3 Hz) induced smaller, but sustained FP activities over the entire stimulus period. Similar frequency-dependencies were observed in CBF(LDF), CBF(ASL) and BOLD responses. A linear relationship between FP and CBF(LDF) was observed for all stimulus frequencies. Stimulation frequency for the maximal cumulative neural and hemodynamic changes is dependent on stimulus duration; 8-12 Hz for short stimulus durations (<10s) and 6-8 Hz for 30-s stimulation. Our findings suggest that neural adaptation should be considered in determining the somatosensory stimulation frequency and duration under isoflurane anesthesia.
منابع مشابه
Relationship between neural, vascular, and BOLD signals in isoflurane-anesthetized rat somatosensory cortex.
Functional magnetic resonance imaging (fMRI) in anesthetized rodents has been commonly performed with alpha-chloralose, which can be used only for terminal experiments. To develop a survival fMRI protocol, an isoflurane (ISO) -anesthetized rat model was systematically evaluated by simultaneous measurements of field potential (FP) and cerebral blood flow (CBF) in the somatosensory cortex. A conv...
متن کاملInsights into the Origin of Spontaneous Coherent BOLD fluctuations in a Resting Rat Brain under Varied Isoflurane Anesthesia Depth
Introduction The coherent fluctuations of blood oxygen level dependent (BOLD) signals have been widely observed in many brain networks of different species at the resting state, and such coherence was hypothesized to result from the underlying anatomical and functional connectivity of brain networks. However, the real mechanism of this observation remained elusive, and even its neural origin is...
متن کاملImaging oxygen consumption in forepaw somatosensory stimulation in rats under isoflurane anesthesia.
The cerebral metabolic rate of oxygen (CMRO2) was dynamically evaluated on a pixel-by-pixel basis in isoflurane-anesthetized and spontaneously breathing rats following graded electrical somatosensory forepaw stimulations (4, 6, and 8 mA). In contrast to alpha-chloralose, which is the most widely used anesthetic in forepaw-stimulation fMRI studies of rats under mechanical ventilation, isoflurane...
متن کاملArterial versus total blood volume changes during neural activity-induced cerebral blood flow change: implication for BOLD fMRI.
Quantifying both arterial cerebral blood volume (CBV(a)) changes and total cerebral blood volume (CBV(t)) changes during neural activation can provide critical information about vascular control mechanisms, and help to identify the origins of neurovascular responses in conventional blood oxygenation level dependent (BOLD) magnetic resonance imaging (MRI). Cerebral blood flow (CBF), CBV(a), and ...
متن کاملComparison of diffusion-weighted high-resolution CBF and spin-echo BOLD fMRI at 9.4 T.
The quantification of blood oxygenation-level dependent (BOLD) functional MRI (fMRI) signals is closely related to cerebral blood flow (CBF) change; therefore, understanding the exact relationship between BOLD and CBF changes on a pixel-by-pixel basis is fundamental. In this study, quantitative CBF changes induced by neural activity were used to quantify BOLD signal changes during somatosensory...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 52 1 شماره
صفحات -
تاریخ انتشار 2010