Estimates of sensitivity and specificity can be biased when reporting the results of the second test in a screening trial conducted in series
نویسندگان
چکیده
BACKGROUND Cancer screening reduces cancer mortality when early detection allows successful treatment of otherwise fatal disease. There are a variety of trial designs used to find the best screening test. In a series screening trial design, the decision to conduct the second test is based on the results of the first test. Thus, the estimates of diagnostic accuracy for the second test are conditional, and may differ from unconditional estimates. The problem is further complicated when some cases are misclassified as non-cases due to incomplete disease status ascertainment. METHODS For a series design, we assume that the second screening test is conducted only if the first test had negative results. We derive formulae for the conditional sensitivity and specificity of the second test in the presence of differential verification bias. For comparison, we also derive formulae for the sensitivity and specificity for a single test design, both with and without differential verification bias. RESULTS Both the series design and differential verification bias have strong effects on estimates of sensitivity and specificity. In both the single test and series designs, differential verification bias inflates estimates of sensitivity and specificity. In general, for the series design, the inflation is smaller than that observed for a single test design.The degree of bias depends on disease prevalence, the proportion of misclassified cases, and on the correlation between the test results for cases. As disease prevalence increases, the observed conditional sensitivity is unaffected. However, there is an increasing upward bias in observed conditional specificity. As the proportion of correctly classified cases increases, the upward bias in observed conditional sensitivity and specificity decreases. As the agreement between the two screening tests becomes stronger, the upward bias in observed conditional sensitivity decreases, while the specificity bias increases. CONCLUSIONS In a series design, estimates of sensitivity and specificity for the second test are conditional estimates. These estimates must always be described in context of the design of the trial, and the study population, to prevent misleading comparisons. In addition, these estimates may be biased by incomplete disease status ascertainment.
منابع مشابه
Evaluation of Students' Vision Screening Test by School Nurse
ABSTRACT Health screening in student, such as Visual screening test usually carry out by school nurses in many rural schools in Iran. While students are in the growth age, visual acuity may be affected by growth. A Study was carried out to evaluate vision screening test on students in Hamadan, Iran. A sample of 878 pupils examined by a school nurse using E- Chart. According to the test, chil...
متن کاملEvaluation of Different Risk Factors for Early Diagnosis of Diabetes Mellitus
Background: The efficacy of various screening variables in detection of diabetes mellitus (DM) is unclear. Objective: To determine the efficacy of various diagnostic tests for type 2 DM. Methods: 1021 inhabitants of Hakimieh district of Tehran aged between 30 and 75 years were studied. Known cases of diabetes and those with factors influencing glucose tolerance test were excluded. Age, sex, f...
متن کاملThe Sensitivity, Specificity and Predictive Values of Snellen Chart Compared to the Diagnostic Test in Amblyopia Screening Program in Iran
Introduction Amblyopia is a leading cause of visual impairment in both childhood and adult populations. Our aim in this study was to assess the epidemiological characteristics of the amblyopia screening program in Iran. Materials and Methods A cross-sectional study was done on a randomly selected sample of 4,636 Iranian children who were referred to screening program in 2013 were participated i...
متن کاملLiu Estimates and Influence Analysis in Regression Models with Stochastic Linear Restrictions and AR (1) Errors
In the linear regression models with AR (1) error structure when collinearity exists, stochastic linear restrictions or modifications of biased estimators (including Liu estimators) can be used to reduce the estimated variance of the regression coefficients estimates. In this paper, the combination of the biased Liu estimator and stochastic linear restrictions estimator is considered to overcom...
متن کاملComparing some screening values of Pap test and visual inspection with acetic acid in the diagnosis of precancerous cervical lesions (2016-2017)
Background: Visual inspection with acetic acid (VIA) is one of the several methods that can serve as an alternative to the Pap test for diagnosis of precancerous lesions in the cervix. This study aimed to compare the screening value of VIA and Pap test in such diagnosis. Materials and Methods: The population of this descriptive study was 304 women who attended Afzalipour Hospital in Kerman, Ir...
متن کامل