Convenient automated conductance volumetric system.
نویسندگان
چکیده
Conventional conductance volumetric systems require ex-vivo calibrations for blood conductivity and parallel conductance. It is often impractical to repeat blood sampling and hypertonic saline infusion for these calibrations. To overcome these limitations, we developed a useful, self-calibrating conductance volumetric system that does not require ex-vivo calibrations. On a conventional 6-electrode catheter, we added an extra electrode close to one of the recording electrodes to estimate blood conductivity. These two electrodes were placed close (0.5 mm) enough so that conductance between them reflected only blood conductivity regardless of cardiac volume. We estimated parallel conductance by the dual-frequency excitation (2 and 20 kHz) method. In 18 anesthetized rabbits, blood conductivity (sigma(est)) thus estimated agreed well with that (sigma(conv)) measured by the conventional ex-vivo blood sampling method (sigma(est) = 1.04sigma(conv)-0.25, R(2) = 0.98, SEE = 0.01 mS/cm, 1.2% error). Parallel conductance (G(p est)) estimated by dual-frequency excitation also agreed well with that (G(p conv)) estimated by the saline injection method (G(p est) = 0.95G(p conv)+4.25, R(2) = 0.87, SEE = 4.0 mS, 6.0% error). Estimated ventricular volume (V(est)) by our system agreed reasonably well with that (V(conv)) by the conventional method (V(est) = 0.93V(conv)+0.01, R(2) = 0.86, SEE = 0.22 ml, 14.7% error). The fact that this self-calibrating conductance volumetric system drastically simplifies volume measurement makes it an attractive tool for the assessment of cardiac function where significant changes in blood conductivity and parallel conductance are inevitable, such as in cardiac surgery.
منابع مشابه
An Automated MR Image Segmentation System Using Multi-layer Perceptron Neural Network
Background: Brain tissue segmentation for delineation of 3D anatomical structures from magnetic resonance (MR) images can be used for neuro-degenerative disorders, characterizing morphological differences between subjects based on volumetric analysis of gray matter (GM), white matter (WM) and cerebrospinal fluid (CSF), but only if the obtained segmentation results are correct. Due to image arti...
متن کاملLutetium-177 DOTATATE Production with an Automated Radiopharmaceutical Synthesis System
Objective(s): Peptide Receptor Radionuclide Therapy (PRRT) with yttrium-90 (90Y) and lutetium-177 (177Lu)-labelled SST analogues are now therapy option for patients who have failed to respond to conventional medical therapy. In-house production with automated PRRT synthesis systems have clear advantages over manual methods resulting in increasing use in hospital-based radiopharmacies. We report...
متن کاملApplication of automated MRI volumetric measurement techniques to the ventricular system in schizophrenics and normal controls.
As an initial approach to computer-automated segmentation of cerebral spinal fluid (CSF) vs. brain parenchyma in MR scans, and the transformation of these data sets into volumetric information and 3D display, we examined the ventricular system in a sample of ten chronic schizophrenics with primarily positive symptoms and 12 normal subjects. While no significant differences were noted between gr...
متن کاملAgreement of Mammographic Measures of Volumetric Breast Density to MRI
BACKGROUND Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. PURPOSE To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a...
متن کاملCost Function Modelling for Semi-automated SC, RTG and Automated and Semi-automated RMG Container Yard Operating Systems
This study analyses the concept of cost functions for semi-automated Straddle Carrier (SC), Rubber Tyred Gantry (RTG) and automated Rail Mounted Gantry (RMG) container yard operating cranes. It develops a generic cost based model for a pair-wise comparison, analysis and evaluation of economic efficiency and effectiveness of container yard equipment to be used for decision-making by terminal pla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Japanese journal of physiology
دوره 52 5 شماره
صفحات -
تاریخ انتشار 2002