Histopathological characterization of corrosion product associated adverse local tissue reaction in hip implants: a study of 285 cases
نویسندگان
چکیده
BACKGROUND Adverse local tissue reaction (ALTR), characterized by a heterogeneous cellular inflammatory infiltrate and the presence of corrosion products in the periprosthetic soft tissues, has been recognized as a mechanism of failure in total hip replacement (THA). Different histological subtypes may have unique needs for longitudinal clinical follow-up and complication rates after revision arthroplasty. The purpose of this study was to describe the histological patterns observed in the periprosthetic tissue of failed THA in three different implant classes due to ALTR and their association with clinical features of implant failure. METHODS Consecutive patients presenting with ALTR from three major hip implant classes (N = 285 cases) were identified from our prospective Osteolysis Tissue Database and Repository. Clinical characteristics including age, sex, BMI, length of implantation, and serum metal ion levels were recorded. Retrieved synovial tissue morphology was graded using light microscopy. Clinical characteristics and features of synovial tissue analysis were compared between the three implant classes. Histological patterns of ALTR identified from our observations and the literature were used to classify each case. The association between implant class and histological patterns was compared. RESULTS Our histological analysis demonstrates that ALTR encompasses three main histological patterns: 1) macrophage predominant, 2) mixed lymphocytic and macrophagic with or without features of associated with hypersensitivity/allergy or response to particle toxicity (eosinophils/mast cells and/or lymphocytic germinal centers), and 3) predominant sarcoid-like granulomas. Implant classification was associated with histological pattern of failure, and the macrophagic predominant pattern was more common in implants with metal-on-metal bearing surfaces (MoM HRA and MoM LHTHA groups). Duration of implantation and composition of periprosthetic cellular infiltrates was significantly different amongst the three implant types examined suggesting that histopathological features of ALTR may explain the variability of clinical implant performance in these cases. CONCLUSIONS ALTR encompasses a diverse range of histological patterns, which are reflective of both the implant configuration independent of manufacturer and clinical features such as duration of implantation. The macrophagic predominant pattern and its mechanism of implant failure represent an important subgroup of ALTR which could become more prominent with increased length of implantation.
منابع مشابه
Modularity in Total Hip Arthroplasty: Benefits, Risks, Mechanisms, Diagnosis, and Management.
Modular implants are currently widely used in total hip arthroplasty because they give surgeons versatility during the operation, allow for easier revision surgery, and can be adjusted to better fit the anatomy of the specific patient. However, modular implants, specifically those that have metal-on-metal junctions, are susceptible to crevice and fretting corrosion. This can ultimately cause im...
متن کاملFretting and corrosion in modular-neck total hip arthroplasty femoral stems.
BACKGROUND During total hip arthroplasty, use of a modular femoral neck on a stemmed implant allows optimization of neck anteversion, length, and offset, resulting in more accurate balance. We performed a retrospective analysis of a consecutive cohort of patients who had undergone total hip arthroplasty with a modular-neck hip system with ceramic-on-ceramic bearings. METHODS We reviewed the r...
متن کاملImplant based differences in adverse local tissue reaction in failed total hip arthroplasties: a morphological and immunohistochemical study
BACKGROUND Adverse local tissue reaction (ALTR) is characterized by periprosthetic soft tissue inflammation composed of a mixed inflammatory cell infiltrate, extensive soft tissue necrosis, and vascular changes. Multiple hip implant classes have been reported to result in ALTR, and clinical differences may represent variation in the soft tissue response at the cellular and tissue levels. The pu...
متن کاملAdverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.
BACKGROUND Femoral stems with dual-taper modularity were introduced to allow additional options for hip-center restoration independent of femoral fixation in total hip arthroplasty. Despite the increasing availability and use of these femoral stems, concerns exist about potential complications arising from the modular neck-body junction. METHODS This was a multicenter retrospective case serie...
متن کاملMetal Ion Levels Are Not Correlated With Histopathology of Adverse Local Tissue Reactions in Taper Corrosion of Total Hip Arthroplasty.
BACKGROUND The underlying biological mechanism in the formation of adverse local tissue reaction in taper corrosion of total hip arthroplasty (THA) remains unknown. This study evaluated whether there was a dose-dependent relationship between metal ion levels, intraoperative tissue damage and ALVAL (aseptic lymphocyte-dominated vasculitis-associated lesion) scores in dual taper THA patients who ...
متن کامل