Characterization of hepatic tumors using [11C]metomidate through positron emission tomography: comparison with [11C]acetate

نویسندگان

  • Anne Roivainen
  • Alexandru Naum
  • Heikki Nuutinen
  • Rauli Leino
  • Heimo Nurmi
  • Kjell Någren
  • Riitta Parkkola
  • Johanna Virtanen
  • Markku Kallajoki
  • Harry Kujari
  • Jari Ovaska
  • Peter Roberts
  • Marko Seppänen
چکیده

BACKGROUND Using positron emission tomography (PET), we compared two tracers, [11C]metomidate ([11C]MTO) and [11C]acetate ([11C]ACE), for the characterization of hepatic tumors. METHODS Thirty-three patients underwent PET with [11C]MTO and [11C]ACE and magnetic resonance imaging (MRI). Based on the histology of the tumor biopsy, 14 patients had hepatocellular carcinoma (HCC), 9 patients had focal nodular hyperplasia (FNH), and 10 patients had other types of hepatic tumors. Tumor uptake was evaluated by calculating the maximum and mean standardized uptake value and tumor-to-liver ratio. RESULTS Altogether, 120 hepatic lesions (59 HCC, 18 FNH, 30 metastases of different primaries, 9 adenomas, and 4 regenerating nodules of liver cirrhosis) were detected by MRI. The overall tumor detection rate was slightly higher for [11C]MTO (39%) than for [11C]ACE (33%). [11C]ACE was more sensitive for HCC detection (50% versus 43%, respectively), whereas [11C]MTO was more sensitive for FNH detection (78% versus 44%, respectively). In HCC patients, the tumor grade correlated with [11C]ACE, but not with [11C]MTO. All of the patients with liver metastases, from various primary tumors (n = 10), were negative for both tracers. CONCLUSIONS Due to low sensitivity, [11C]MTO and [11C]ACE PET have only limited value in diagnosing hepatic tumors.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of Brain Tumors Using Amino Acid Transport PET Imaging With 18F- Fluciclovine: A Comparison Study With L-Methyl-11C-Methionine PET Imaging

Objective(s): 18F-fluciclovine (trans-1-amino-3-[18F] fluorocyclobutanecarboxylic acid, [FACBC]) is an artificial amino acid radiotracer used for positron emission tomography (PET) studies, which is metabolically stable in vivo and has a long half-life. It has already been shown that FACBC-PET is useful for glioma imaging. However, there have been no reports evaluating the efficiency of FACBC-P...

متن کامل

Clinical positron emission tomography for brain tumors: comparison of fludeoxyglucose F 18 and L-methyl-11C-methionine.

PURPOSE To evaluate the differences between fludeoxyglucose F 18 (FDG) and L-methyl-11C-methionine (11C-methionine) as tracers for positron emission tomography (PET) in the evaluation of brain tumors. METHODS We analyzed 10 patients with histologically verified cerebral glioma or meningioma and 1 patient with a neuroradiologic diagnosis of low-grade glioma by using FDG, 11C-methionine, and PE...

متن کامل

Noninvasive quantitation of regional myocardial oxygen consumption in vivo with [1-11C]acetate and dynamic positron emission tomography.

The usefulness of [1-11C]acetate as a tracer of overall myocardial oxidative metabolism for use with positron emission tomography has been investigated in 12 closed-chest dogs. Myocardial 11C activity clearance kinetics after intravenous administration of [1-11C]acetate in dogs have been determined noninvasively by positron emission tomography. Biexponential fitting of regional myocardial 11C t...

متن کامل

Novel parameter estimation methods for 11C-acetate dual-input liver model with dynamic PET.

The successful investigation of 11C-acetate in positron emission tomography (PET) imaging for marking hepatocellular carcinoma (HCC) has been validated by both clinical and quantitative modeling studies. In the previous quantitative studies, all the individual model parameters were estimated by the weighted nonlinear least squares (NLS) algorithm. However, five parameters need to be estimated s...

متن کامل

Application of Dual Phase Imaging of 11C-Acetate Positron Emission Tomography on Differential Diagnosis of Small Hepatic Lesions

OBJECTIVE Previously we observed that dual phase 11C-acetate positron emission tomography (AC-PET) could be employed for differential diagnosis of liver malignancies. In this study, we prospectively evaluated the effect of dual phase AC-PET on differential diagnosis of primary hepatic lesions of 1-3 cm in size. METHODS 33 patients having primary hepatic lesions with size of 1-3 cm in diameter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013