Comparative Study of Evolutionary Computing Methods for Parameter Estimation of Power Quality Signals

نویسندگان

  • V. Ravikumar Pandi
  • Bijaya K. Panigrahi
چکیده

Recently utilities and end users become more concerned about power quality issues because the load equipments are more sensitive to various power quality disturbances, such as harmonics and voltage fluctuation. Harmonic distortion and voltage flicker are the major causes in growing concern about electric power quality. Power quality disturbance monitoring plays an important role in the deregulated power market scenario due to competitiveness among the utilities. This paper presents an evolutionary algorithm approach based on Adaptive Particle Swarm Optimization (APSO) to determine the amplitude, phase and frequency of a power quality signal. In this APSO algorithm the time varying inertia weight is modified as rank based, and re-initialization is used to increase the diversity. In this paper, to the authors highlight the efficacy of different evolutionary optimization techniques like classical PSO, Constriction based PSO, Clonal Algorithm (CLONALOG), Adaptive Bacterial Foraging (ABF) and the proposed Adaptive Particle Swarm Optimization (APSO) to extract different parameters like amplitude, phase and frequency of harmonic distorted power quality signal and voltage flicker. DOI: 10.4018/jaec.2010040102 International Journal of Applied Evolutionary Computation, 1(2), 28-59, April-June 2010 29 Copyright © 2010, IGI Global. Copying or distributing in print or electronic forms without written permission of IGI Global is prohibited. well as industrial plant rectifiers and inverters. These electronic types of loads cause quasistatic harmonic dynamic voltage distortions, inrush, pulse type current phenomenon with excessive harmonics and high distortion. A power quality (PQ) problem usually involves a variation in the electric service voltage or current, such as voltage dips and fluctuations, momentary interruptions, harmonics and oscillatory transients causing failure or mal-operation of the power service equipment. In order to improve electric power quality, the sources and causes of such disturbances must be known before appropriate mitigating action can be taken. However, in order to determine the causes and sources of disturbances, one must have the ability to detect and localize these disturbances. Estimation of amplitude and phase of fundamental, as well as harmonic signals has been one of the important tasks in measurement, control, relaying protection, distribution automation, and intelligent instrumentation of power system. Accurate power fundamental frequency is a necessity to check the state of health of the power index, and a guarantee for accurate quantitative measurement of power parameters, such as voltages, currents, active power, reactive power, and energy, and so on, in multifunction power meters under steady states. It is more difficult to precisely estimate the fundamental frequency of power systems in presence of harmonics and noises than under sinusoidal condition. It is essential to seek and develop some effective algorithms for accurate estimation of the instantaneous fundamental frequency of power systems under non-sinusoidal conditions. Several methods employing digital algorithms have been developed for the estimation of parameters like amplitude, phase and frequency of power quality signals. Algorithms based on Fast Fourier Transform (FFT) have been widely used for the purpose (Chen, 1997; IEEE Standard, 1993). The FFT method suffers from the major problem such as resolution, spectrum leakage and picket-fence effects. As the system frequency deviates from the nominal value, the leakage error becomes more (Probabilistic aspects Task Force, 1998). Some of the pit falls of DFT was suggested in (Girgis & Ham, 1980). The leakage effects of system frequency variation on the measurements of harmonic and flicker have never been accurately determined, so some serious errors might happen in the related measurements. Digital algorithms based on Least Error Square (LES) state estimation technique (Lobos, Kozina, & Koglin, 2001; Sachdev & Giray, 1985; Soliman & El-Hawary, 1999), Least Absolute Value (LAV) estimation (Soliman, Christensen, Kelly, & El-Naggar, 1992) are more common to estimate the parameters of a power quality signal. The above algorithms are not suitable for the non-stationary signals. The other digital algorithm based on Kalman Filtering is a stochastic dynamic filtering algorithm, mostly suitable for non-stationary signals. This method leads to fast and accurate estimation of power system signal amplitude and phase. This method has been applied for finding the parameters of the voltage flicker signal, harmonic signals and has been reported in (Dash, Jena, Panda, & Routray, 2000; Routray, Pradhan, & Rao, 2002). However the algorithm requires an accurate guess of system frequency. The use of Fourier Linear Combiner for harmonic estimation in distorted power signals is reported in (Dash, Swain, Liew, & Rahman, 1996; Dash, Pradhan, & Salama, 2002). Another method based on sample count and interpolation estimation technique is reported in (Aghazadeh, Lesani, Sanaye-Pasand, & Ganji, 2005) for frequency and amplitude estimation of power system signals. Besides the above digital techniques, some of the intelligent techniques like Artificial Neural Network (ANN), Expert system (ES) has been applied for amplitude, phase and frequency estimation of distorted power signals (Kandil, Sood, Khorasani, & Patel, 1992; Martins, Oliveira, & Goncalves, 2000; Mori, 1992; Osowski, 1992). Soft computing techniques like Genetic Algorithm (GA) (El-Naggar & AL-Hasawi, 2006; El-Zonkoly, 2005), Simulated Annealing (SA) (Soliman, Mantaway, & El-Hawary, 2004) have also been applied for power quality analysis. A new algo30 more pages are available in the full version of this document, which may be purchased using the "Add to Cart" button on the product's webpage: www.igi-global.com/article/comparative-study-evolutionarycomputing-methods/43539?camid=4v1 This title is available in InfoSci-Journals, InfoSci-Journal Disciplines Computer Science, Security, and Information Technology. Recommend this product to your librarian: www.igi-global.com/e-resources/libraryrecommendation/?id=2

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New High Frequency Grid Impedance Estimation Technique for the Frequency Range of 2 to150 kHz

Grid impedance estimation is used in many power system applications such as grid connected renewable energy systems and power quality analysis of smart grids. The grid impedance estimation techniques based on signal injection uses Ohm’s law for the estimation. In these methods, one or several signal(s) is (are) injected to Point of Common Coupling (PCC). Then the current through and voltage of ...

متن کامل

Application of statistical techniques and artificial neural network to estimate force from sEMG signals

This paper presents an application of design of experiments techniques to determine the optimized parameters of artificial neural network (ANN), which are used to estimate force from Electromyogram (sEMG) signals. The accuracy of ANN model is highly dependent on the network parameters settings. There are plenty of algorithms that are used to obtain the optimal ANN setting. However, to the best ...

متن کامل

Application of Soft Computing Methods for the Estimation of Roadheader Performance from Schmidt Hammer Rebound Values

Estimation of roadheader performance is one of the main topics in determining the economics of underground excavation projects. The poor performance estimation of roadheader scan leads to costly contractual claims. In this paper, the application of soft computing methods for data analysis called adaptive neuro-fuzzy inference system- subtractive clustering method (ANFIS-SCM) and artificial  neu...

متن کامل

Grid Impedance Estimation Using Several Short-Term Low Power Signal Injections

In this paper, a signal processing method is proposed to estimate the low and high-frequency impedances of power systems using several short-term low power signal injections for a frequency range of 0-150 kHz. This frequency range is very important, and thusso it is considered in the analysis of power quality issues of smart grids. The impedance estimation is used in many power system applicati...

متن کامل

Estimation of harmonic interference parameters of surface-NMR signal using an adaptive method and residual signal power

Surface nuclear magnetic resonance (surface-NMR) method is a well-known tool for determining the water-bearing layers and subsurface resistivity structure. Harmonic interference is an inevitable interference in surface-NMR measurements. Accurate estimation of harmonic interference parameters (i.e., fundamental frequency, phase and amplitude) leads to better retrieval of power-line harmonics and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IJAEC

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2010