Interrelating sentinel event alert #38 with the ACR guidance document on MR safe practices: 2013. An MRI accreditation safety review tool.

نویسندگان

  • Tobias Gilk
  • Emanuel Kanal
چکیده

When, in 2008, the Joint Commission released its Sentinel Event Alert #38 regarding MRI safety, it joined the ACR's Guidance Document on MR Safe Practices as one of two radiology best-practice documents establishing MR safety protections. However, particularly for MR providers who held both modality-level accreditation from the ACR, and enterprise-level accreditation from the Joint Commission, there has been confusion about which institution's standard takes precedence, or whether there are inherent conflicts between the two. With the release of the 2013 update to the ACR Guidance Document on MR Safe Practices, the authors have cross-referenced the performance criteria of both MR safety standards, and correlated the ACR Guidance Document performance criteria with the Joint Commission's Environment of Care standards.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A national survey of MRI safety practices in Ghana

Objective The aim of the present study was to assess current MRI safety practices among MRI facilities in Ghana, and their compliance with the 2013 American College of Radiology (ACR) guidance document on MR safe practices. Material and methods A questionnaire developed from the 2013 ACR Guidance Document was used to collect information on magnetic field strengths, MR safety policy and compli...

متن کامل

ACR guidance document on MR safe practices: 2013.

Because there are many potential risks in the MR environment and reports of adverse incidents involving patients, equipment and personnel, the need for a guidance document on MR safe practices emerged. Initially published in 2002, the ACR MR Safe Practices Guidelines established de facto industry standards for safe and responsible practices in clinical and research MR environments. As the MR in...

متن کامل

American College of Radiology White Paper on MR Safety: 2004 update and revisions.

here are potential risks in the MR environment not only for the patient, but also for the attending health care professionals, accompanying family members, and others who may find themselves in the magnetic fields of MR scanners, such as security or housekeeping personnel, firefighters, and police. The following is an updated report of the American College of Radiology (ACR) Blue Ribbon Panel o...

متن کامل

Overview of the Acr Mri Accreditation Phantom

• Geometric Distortion • Spatial Resolution • Slice thickness and position • Interslice Gap • Estimate of Image Bandwidth • Low Contrast Detectability • Image Uniformity • Signal-to-Noise Ratio (SNR) • Physical and Electronic Slice Offset • Landmark This document contains phantom specifications and materials and a brief description of image analysis. For a more complete description of the ACR M...

متن کامل

Preventing accidents and injuries in the MRI suite.

Magnetic resonance imaging (MRI) was applied to health care in the late 1970s to provide never-before-seen twoand threedimensional views of body tissue and structure. Today, more than 10 million MRI, or MR, scans are done in the United States each year. (1) While the capabilities of the MRI scanner are well-recognized, its inherent dangers may not be as well known. The following types of injury...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 2013