EXTENDED REPORT Clinical value of gallium-67 scintigraphy in assessment of disease activity in Wegener’s granulomatosis
نویسندگان
چکیده
Background: Diagnosis of active pulmonary and paranasal involvement in patients with Wegener’s granulomatosis (WG) can be difficult. The diagnostic value of gallium-67 scintigraphy in WG is unclear. Objective: To evaluate the added diagnostic value of gallium-67 scintigraphy in patients with WG with suspected granulomatous inflammation in the paranasal and chest regions. Methods: Retrospectively, the diagnostic contribution of chest and head planar gallium scans in 40 episodes of suspected vasculitis disease activity in 28 patients with WG was evaluated. Scans were grouped into normal or increased uptake for each region. Histological proof or response to treatment was the “gold standard” for the presence of WG activity. Results: WG activity was confirmed in 8 (20%) episodes, with pulmonary locations in three, paranasal in four, and both in one (n=7 patients); all these gallium scans showed increased gallium uptake (sensitivity 100%). Gallium scans were negative for the pulmonary area in 23/36 scans (specificity 64%), and negative for paranasal activity in 13/16 scans (specificity 81%) in episodes without WG activity. Positive predictive value of WG activity for lungs and paranasal region was 24% and 63%, respectively, negative predictive value was 100% for both regions. False positive findings were caused by bacterial or viral infections. Conclusion: Gallium scans are clinically helpful as a negative scan virtually excludes active WG. Gallium scintigraphy of chest and nasal region has a high sensitivity for the detection of disease activity in WG. However, because of positive scans in cases of bacterial or viral infections, specificity was lower.
منابع مشابه
Clinical value of gallium-67 scintigraphy in assessment of disease activity in Wegener's granulomatosis.
BACKGROUND Diagnosis of active pulmonary and paranasal involvement in patients with Wegener's granulomatosis (WG) can be difficult. The diagnostic value of gallium-67 scintigraphy in WG is unclear. OBJECTIVE To evaluate the added diagnostic value of gallium-67 scintigraphy in patients with WG with suspected granulomatous inflammation in the paranasal and chest regions. METHODS Retrospective...
متن کاملBilateral Facial Paralysis and Otitis Media as the First Presentations of Wegener’s Granulomatosis: A Case Report
Introduction: Cranial nerve palsy in Wegener’s granulomatosis is a curious incident, particularly if it occurs without kidney or lung involvement. In a review of medical articles, only 1 case of Wegener’s granulomatosis with bilateral facial nerve palsy was found. Case Presentation: The patient was a 16-year-old female who presented with pain and hearing ...
متن کاملOtologic Manifestations and Progression in Patients with Wegener’s granulomatosis: A Survey in 55 Patients
Introduction: Granulomatosis with polyangiitis (GPA; also known as Wegener’s granulomatosis) is a primary systemic vasculitis involving the ear, nose and throat system (ENT) and lower respiratory tract. Because of the lack of knowledge regarding the clinical findings of GPA due to the limited number of studies, the current study was designed to investigate the prevalence and nature of the otolo...
متن کاملEpidemiology of Vasculitides in Khorasan Province, Iran
Vasculitides are a heterogeneous group of more than 20 diseases defined by inflammation and destruction of blood vessels. We aimed to study the demographic characteristics of the primary vasculitides in the North East of Iran. We retrospectively studied the medical records of patients diagnosed with any kind of vasculitis at the Clinic and Department of Rheumatology of the Imam Reza Hospital, M...
متن کاملSensitivity of gallium scintigraphy for evaluation of recurrent lymphoma: Comparison of planar and SPECT imaging
Introduction: Although PET scanning using F-18[FDG] is considered the superior radiotracer for tumnor imaging, Gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. One of the strategies to improve the diagnostic accuracy of Gallium is to perform SPECT which is reported to be more sensitive compared to planar imaging. In this study we compa...
متن کامل