Dual-channel spectral-domain optical-coherence tomography system based on 3 × 3 fiber coupler for extended imaging range.
نویسندگان
چکیده
We have demonstrated a dual-channel multiplexing spectral-domain optical-coherence tomography (SD-OCT) system based on a 3×3 fiber coupler for extended imaging range of whole human eye depth, with a single light source and spectrometer. OCT images of anterior segments of a human eye were sequentially performed and constructed to demonstrate an extended depth range as large as 15 mm in air. A good quality OCT image of the whole anterior segment of an eye was present. Furthermore, whole eye segmental imaging was performed and ocular distances were calculated to show the validation of the system for whole eye morphological measurement.
منابع مشابه
Ultrawideband photonic crystal fiber coupler for multiband optical imaging system.
We report a photonic crystal fiber (PCF) coupler having an ultrawide spectral bandwidth keeping single mode operation. The use of the PCF coupler in a fiber-based optical coherence tomography (OCT) system enables us to handle the wide spectral bands of various light sources, including superluminescent diodes (SLDs) at 1300 nm and 820 nm, Ti:sapphire lasers, and white-light sources. The multiban...
متن کاملHomodyne en face optical coherence tomography.
We demonstrate, for what we believe to be the first time, the use of a 3 x 3 fiber-optic coupler to realize a homodyne optical coherence tomography (OCT) system for en face imaging of highly scattering tissues and turbid media. The homodyne OCT setup exploits the inherent phase shifts between different output ports of a 3 x 3 fiber-optic coupler to extract amplitude information of a sample. Our...
متن کاملAn all-fiber-optic endoscopy platform for simultaneous OCT and fluorescence imaging
We present an all-fiber-optically based endoscope platform for simultaneous optical coherence tomography (OCT) and fluorescence imaging. This design entails the use of double-clad fiber (DCF) in the endoscope for delivery of OCT source and fluorescence excitation light while collecting the backscattered OCT signal through the single-mode core and fluorescence emission through the large inner cl...
متن کاملبررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک
Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 53 24 شماره
صفحات -
تاریخ انتشار 2014