Treatment efficiency of conventional vs self-ligating brackets: effects of archwire size and material.

نویسندگان

  • Nicholas R Turnbull
  • David J Birnie
چکیده

INTRODUCTION In this prospective clinical study, we assessed the relative speed of archwire changes, comparing self-ligating brackets with conventional elastomeric ligation methods, and further assessed this in relation to the stage of orthodontic treatment represented by different wire sizes and types. METHODS The time taken to remove and ligate archwires for 131 consecutive patients treated with either self-ligating or conventional brackets was prospectively assessed. The study was carried out in the orthodontic department of a district general hospital in the United Kingdom. The main outcome measure was the time to remove or place elastomeric ligatures or open/close self-ligating brackets for 2 matched groups of fixed appliance patients: Damon2 self-ligating bracket (SDS Ormco, Orange, Calif) and a conventional mini-twin bracket (Orthos, SDS Ormco). The relative effects of various wire sizes and materials on ligation times were investigated. The study was carried out by 1 operator experienced in the use of self-ligating and conventional brackets. RESULTS The Damon2 self-ligating system had a significantly shorter mean archwire ligation time for both placing (P <.001) and removing (P <.01) wires compared with the conventional elastomeric system. Ligation of an archwire was approximately twice as quick with the self-ligating system. Opening a Damon slide was on average 1 second quicker per bracket than removing an elastic from the mini-twin brackets, and closing a slide was 2 seconds faster per bracket. This difference in ligation time between the Damon2 and the conventional mini-twin brackets became more marked for larger wire sizes used in later treatment stages. CONCLUSIONS The type of bracket and the size of wire used are statistically significant predictors for speed of ligation and chairside time. The self-ligating system offered quicker and arguably more efficient wire removal and placement for most orthodontic treatment stages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type

OBJECTIVE This study aimed to compare the frictional force (FR) in self-ligating brackets among different bracket-archwire angles, bracket materials, and archwire types. METHODS Passive and active metal self-ligating brackets and active ceramic self-ligating brackets were included as experimental groups, while conventional twin metal brackets served as a control group. All brackets were maxil...

متن کامل

Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

OBJECTIVE To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. MATERIAL AND METHODS Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek) with three (0, 5, and 10 degrees) slot angulation attached with elastomeric...

متن کامل

Evaluation of rotational control and forces generated during first-order archwire deflections: a comparison of self-ligating and conventional brackets.

The purpose of this study was to compare the activation and deactivation forces generated during first-order archwire deflections when different sizes and types of NiTi wires are paired with conventional and self-ligating brackets (SLBs) and to evaluate the rotational control between these same archwire and bracket combinations. Four maxillary premolar SLBs (Damon 3MX, SmartClip, Carriere, and ...

متن کامل

Torque expression in stainless steel orthodontic brackets. A systematic review.

OBJECTIVE To evaluate the quantitative effects on torque expression of varying the slot size of stainless steel orthodontic brackets and the dimension of stainless steel wire, and to analyze the limitations of the experimental methods used. MATERIALS AND METHODS In vitro studies measuring torque expression in conventional and self-ligating stainless steel brackets with a torque-measuring devi...

متن کامل

Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study

OBJECTIVE To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. METHODS Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics

دوره 131 3  شماره 

صفحات  -

تاریخ انتشار 2007