Valve repair using biodegradable ring annuloplasty: from bench to long-term clinical results
نویسندگان
چکیده
Annulus remodeling and stabilization with a ring is a necessary step in mitral and tricuspid valve repair to maintain effective leaflet coaptation and improve long-term results. Although conventional rings meet the basic needs of adults, they do not preserve the changes in shape and size occurring during the cardiac cycle, and do not allow growth of the native annulus in children. The bioring annuloplasty ring was developed to allow for annular stabilization, while remaining biodegradable and allowing for growth. It is a curved "C" segment of poly-1,4-dioxanone polymer located on a non-degradable polyvinyl monofilament suture equipped with a stainless steel needle at each extremity. This ring is inserted subendocardially directly into the mitral or tricuspid annulus, away from blood contact. Animal model experiments have shown that it degrades within 12 months of implantation and is replaced by fibrous tissue, which stabilizes the annulus durably, while allowing for annular growth in children. We review the published data, from bench to bedside, as well as the early, mid and long-term clinical outcomes using the biodegradable ring, which shows that biodegradable rings remodel the annulus, reinforce the repair, restore the function of the atrioventricular valve and maintain the three dimensional dynamic motion and geometry of the mitral and tricuspid valves annulus. Growth potential is preserved in children. The mid- and long-term results showed that degradation of the device occurred without negative observable consequences.
منابع مشابه
New technology: valve repair using biodegradable rings.
OBJECTIVE To introduce a new concept in the annuloplasty technology. Although rigid and flexible rings meet the basic needs of adults, they do not preserve the changes in shape and size occurring during the cardiac cycle. If implanted in children, such materials do not allow growth of the native annulus. METHODS From March 2003 to March 2007, 207 patients underwent mitral and/or tricuspid val...
متن کاملTricuspid valve repair with an annuloplasty ring results in improved long-term outcomes.
BACKGROUND The purpose of this study was to compare the long-term results of tricuspid valve (TV) repair with or without an annuloplasty ring. METHODS AND RESULTS 702 patients underwent TV repair at our institution (1978 to 2003), of which 493 had, predominantly, a De Vega procedure (no ring) and 209 had an annuloplasty ring (ring). TV pathology was functional (secondary) in 74% of patients. ...
متن کاملBiodegradable materials for tricuspid valve repair in infective endocarditis.
We read with interest the report by Akinosoglou et al. [1] on the surgical management of tricuspid valve infective endocarditis. We congratulate the authors for their excellent and extensive review of the literature and for providing useful management algorithms. We would like to discuss biodegradable materials in this patient group. The authors divide the surgical techniques into non-prostheti...
متن کاملBiodegradable materials for surgical management of infective endocarditis: new solution or a dead end street?
BACKGROUND One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in...
متن کاملReply to Myers et al.
The authors agree with Myers et al. [1] that biodegradable materials represent a useful alternative in the management of tricuspid valve endocarditis repair. Our statement of dividing tricuspid valve repair choices in prosthetic and non-prosthetic techniques adequately sets the main cornerstones of surgical therapy: first, minimizing, as much as possible, the resulting valve regurgitation follo...