Interference of drug-eluting stents with endothelium-dependent coronary vasomotion: evidence for device-specific responses.
نویسندگان
چکیده
BACKGROUND There is evidence that endothelial coverage of drug-eluting stents might be delayed or absent, a risk factor for late thrombotic events. We studied the effects of different drug-polymer-device iterations on endothelium-dependent coronary vasomotion. Systemic markers of endothelial inflammation were correlated with coronary vasomotor changes. METHODS AND RESULTS Patients with paclitaxel-eluting stents (n=11), sirolimus-eluting stents (n=21), biolimus A9-eluting stents (n=28), zotarolimus-eluting stents (n=10), and bare-metal stents (n=13) were studied 10, 9, 9, 9, and 12 months after implantation, respectively. Endothelium-dependent coronary vasomotion was tested proximally and distally to the stent and at a reference vessel segment during atrial pacing at increasing heart rates by quantitative coronary angiography. Indexes of platelet-monocyte binding and other biomarkers were studied in a subgroup of 19 patients. The baseline characteristics and hemodynamics of the patients in the different stent groups were comparable. Significant differences were observed across the 5 stent groups, concerning the vasomotion of segments proximal (P=0.006) and distal (P=0.003) to the stent. Normal vasomotion (vasodilatation) was maintained in the biolimus A9-eluting stent, zotarolimus-eluting stent, and bare-metal stent groups, whereas vasoconstriction was observed in the sirolimus-eluting stent and paclitaxel-eluting stent groups. Platelet-monocyte binding in whole blood showed a significant inverse correlation with vasomotion in reference but not in segments adjacent to the stent (r=-0.57; P=0.01). CONCLUSIONS Paclitaxel-eluting stents and sirolimus-eluting stents seem to cause endothelial dysfunction of the implanted vessel, whereas biolimus A9-eluting stents and zotarolimus-eluting stents behave more closely to bare-metal stents, with preserved endothelial vasomotor response. Coronary vasoconstriction was not associated with detectable systemic endothelial activation.
منابع مشابه
Transient impairment of vasomotion function after successful chronic total occlusion recanalization.
OBJECTIVES The aim of our study was to assess coronary vasomotion after successful revascularization of chronic total occlusion (CTO). BACKGROUND It is largely unknown whether the recovery of anterograde flow after CTO recanalization with drug-eluting stent implantation affects vascular function in distal coronary segments. METHODS One hundred consecutive CTOs successfully treated with drug...
متن کاملDrug-eluting stent implantation could be associated with long-term coronary endothelial dysfunction.
Drug-eluting stent (DES) implantation may be associated with endothelial dysfunction. However, changes in long-term endothelial function based on the type of DES remain largely unknown. We assessed coronary endothelial function after DES implantation compared to bare-metal stents (BMS) and determined the differences according to DES type. Patients who had single BMS or DES implantation in the l...
متن کاملCoronary Bioresorbable Vascular Scaffold Use in the Treatment of Coronary Artery Disease.
Bioresorbable vascular scaffolds (BVS) represent a promising novel approach for the treatment of coronary artery disease. BVS promise to address some of the well-known limitations of current drug-eluting stents, while providing a transient scaffolding of the vessel to prevent acute vessel closure/recoil. Drug elution by BVS prevents neointimal proliferation in a similar fashion to drug-eluting ...
متن کاملMultianalysis with optical coherence tomography and vasomotion in everolimus-eluting stents and everolimus-eluting biovascular scaffolds: the MOVES trial
Aims To compare endothelium-dependent vasomotor function and vascular healing 15 months after implantation of two new-generation drug-eluting stents and biovascular scaffolds (BVS). Methods and results A total of 28 patients previously treated with a SYNERGY stent (bioabsorbable polymer everolimus-eluting stents (BP-EES)), a PROMUS stent (persistent polymer everolimus-eluting stents (PP-EES))...
متن کاملRenal Denervation Suppresses Coronary Hyperconstricting Responses After Drug-Eluting Stent Implantation in Pigs In Vivo Through the Kidney-Brain-Heart Axis.
OBJECTIVE Drug-eluting stent-induced coronary hyperconstricting responses remain an important issue. The adventitia harbors a variety of components that potently modulate vascular tone, including sympathetic nerve fibers (SNF) and vasa vasorum. Catheter-based renal denervation (RDN) inhibits sympathetic nerve activity. We, thus, examined whether RDN suppresses drug-eluting stent-induced coronar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 1 3 شماره
صفحات -
تاریخ انتشار 2008